Product Description
The ALSTOM N895314513L is a specialized communication or processor module engineered for the GE/Alstom Mark VI and Mark VIe family of turbine control systems. This module serves as a critical node within the control architecture, most likely functioning as a communication processor, network interface card, or a specialized application controller for managing specific turbine subsystems. Its primary role is to facilitate high-speed, deterministic data exchange between the main Turbine Control Unit (TCU) processor and other system components, remote I/O, or external supervisory networks like a plant DCS. The ALSTOM N895314513L ensures that critical data for control, sequencing, and protection is transmitted with the low latency and high reliability required for safe turbine operation.
Product Parameters
-
Model: ALSTOM N895314513L.
-
Function: Communication Processor / Network Interface Module for Mark VI/e.
-
Communication Protocols: Typically supports key industrial protocols for integration, such as Modbus TCP/IP, Modbus RTU, and Ethernet Global Data (EGD). May also handle the proprietary peer-to-peer network within the Mark VIe system.
-
Host Interface: Connects directly to the VME backplane of the Mark VI/e controller, allowing direct access to the control processor’s data tables.
-
Network Ports: Features one or more Ethernet ports (e.g., 10/100Base-TX) for connection to plant networks.
-
Processing Power: Contains a dedicated microprocessor for managing protocol stacks, data routing, and communication tasks independently of the main CPU.
-
Memory: Includes onboard RAM and non-volatile memory for firmware and configuration storage.
-
Diagnostic Indicators: Equipped with status LEDs for power, network link/activity, module health, and communication status.
Advantages and Features
-
Deterministic Data Handling: Designed for the real-time demands of turbine control, ensuring predictable communication latency between the controller and external systems, which is vital for coordinated control and timely alarm reporting.
-
Secure Gateway Functionality: Acts as a controlled and isolated gateway, allowing necessary data exchange for monitoring and supervision while protecting the integrity of the real-time control network from external cyber threats and traffic interference.
-
High Reliability and Availability: Built to the same rigorous standards as other Mark VIe components, ensuring continuous, fault-resistant operation critical for minimizing turbine downtime.
-
Simplified System Integration: By providing standard protocol interfaces, the ALSTOM N895314513L dramatically reduces the complexity and cost of integrating the turbine controller into a wider plant Distributed Control System (DCS) or SCADA.
-
Comprehensive Diagnostics: Offers module-level diagnostics to quickly identify network issues, communication faults, or hardware problems, facilitating rapid troubleshooting.
Application Cases in Relevant Fields
-
Plant-Wide DCS Integration: The ALSTOM N895314513L is deployed to connect a gas or steam turbine’s Mark VIe controller to a central plant DCS (e.g., Emerson Ovation, Siemens), enabling operators to monitor and control the turbine from the main plant control room.
-
Remote Monitoring and Diagnostics Centers: Serves as the secure data conduit for transmitting turbine health and performance data to OEM or third-party remote diagnostic centers, enabling predictive maintenance and performance optimization.
-
Data Historian and Plant Information Systems: Channels operational data (vibrations, temperatures, efficiencies) to plant historians like OSIsoft PI or GE Digital’s Historian for long-term analysis, reporting, and regulatory compliance.
-
Multi-Unit Coordination in Power Plants: In plants with multiple turbines, modules like the ALSTOM N895314513L enable communication between units for coordinated load dispatch, start-up sequencing, and grid support functions.
Comparisons with Competing Products
Compared to generic industrial protocol converters or Ethernet gateways from companies like ProSoft or Red Lion, the ALSTOM N895314513L is a proprietary, system-embedded solution with distinct advantages.
-
Deep System Integration and Performance: It is not just a gateway; it is an integral part of the Mark VIe’s operating system. It has direct, low-level access to controller data with deterministic performance that generic devices cannot match, especially for time-critical data.
-
Unified Engineering and Support: Configuration and diagnostics for the ALSTOM N895314513L are managed within the same ToolboxST engineering environment used for the entire turbine controller. This unified approach simplifies lifecycle management compared to managing a separate third-party device with its own software tools.
-
OEM Certification for Critical Systems: Its use is validated and supported by GE for critical turbine control applications. Introducing a non-OEM communication device can introduce unqualified risks and complicate support claims. For guaranteed compatibility and system integrity, the authentic ALSTOM N895314513L is the specified choice.
Selection Suggestions and Precautions
-
Confirm Specific System Compatibility: Verify that the ALSTOM N895314513L is listed as compatible with your specific Mark VI or Mark VIe system series and controller model. Using an incompatible revision can cause communication failures.
-
Define Communication Requirements Clearly: Before procurement, specify the required protocols (Modbus TCP, EGD), data points, update rates, and IP addressing scheme to ensure the module can be configured to meet plant network requirements.
-
Source Exclusively from Authorized Channels: Purchase this critical communication component only from GE Vernova authorized distributors. Counterfeit or unauthorized modules pose severe cybersecurity risks and can lead to unreliable data communication.
-
Engage IT/OT Cybersecurity Early: The installation of this module creates a network interface for the turbine. Its integration must be planned and executed with the plant’s IT/OT cybersecurity team to implement proper network segmentation, firewall rules, and access controls from the outset.
-
Plan for Software Configuration and Testing: Installing or replacing the ALSTOM N895314513L requires configuration in ToolboxST to define its role, IP settings, and data mapping. This will necessitate a controller download and must be followed by thorough communication testing with the external system (e.g., DCS).
-
Maintain Firmware Vigilance: Inquire about the firmware version loaded on the module and check for any required updates from GE to address known issues or vulnerabilities. Keep a record of the firmware version as part of the system documentation.

IS420ESWBH3A GE PLC