The ALSTOM IR139-1 is a specialized interface or relay module integral to Alstom’s comprehensive automation and protection systems. This model is specifically designed to serve as an intermediate or auxiliary relay, providing essential signal conditioning, isolation, and switching functions within complex control panels. The core purpose of the ALSTOM IR139-1 is to reliably convert or amplify control signals, ensuring that low-power logic commands from a PLC or protection device can safely and effectively command higher-power field apparatus. Its use is critical for segregating different voltage levels and protecting sensitive electronic circuits from transients in the field. Implementing the genuine IR139-1 module guarantees the design integrity and operational safety of the overall control system. For engineers maintaining Alstom-centric architectures, this component is a trusted and specified solution.
Product Parameters
-
Manufacturer / Brand: Alstom
-
Product Type: Interface Relay Module / Auxiliary Relay
-
Model: IR139-1
-
Series: Part of the IR series of interface relays.
-
Contact Configuration: Typically features a multi-pole (e.g., 2 or 3 Form-C contacts) relay for flexible switching applications.
-
Coil Control Voltage: Available in standard industrial DC or AC voltages (e.g., 24V DC, 48V DC, 110V AC, 220V AC) as defined by the order suffix.
-
Contact Rating: Rated for switching inductive and resistive loads up to a specified current (e.g., 5-10A at 250V AC) for control circuits.
-
Mounting: Designed for DIN-rail mounting (35mm) for easy installation in control cabinets.
-
Isolation: Provides high electrical isolation between the coil circuit and the contact circuit for safety and noise immunity.
-
Indication: Features an LED or mechanical flag to visually indicate the energization status of the relay.
-
Termination: Utilizes screw-clamp or spring-cage terminals for secure wire connection.
Advantages and Features
-
High Reliability: Engineered for a high mechanical and electrical lifespan, ensuring dependable operation over millions of cycles.
-
Excellent Signal Isolation: Provides robust galvanic isolation between control and load circuits, protecting sensitive PLC outputs from voltage spikes and electrical noise.
-
Versatile Switching: The use of Form-C (changeover) contacts allows for a wide range of wiring configurations (NO, NC, or break-before-make switching).
-
Compact and Modular Design: Its DIN-rail format allows for high-density mounting, saving panel space, and its modularity facilitates easy replacement.
-
Clear Status Indication: Immediate visual feedback of the relay’s state simplifies troubleshooting and maintenance activities.
-
Broad Compatibility: Designed to interface seamlessly with a wide range of Alstom and third-party control devices, acting as a universal signal amplifier.
Application Cases in Key Fields
-
Power Substation Control: Used extensively in protection relay panels to amplify trip/close signals from numerical relays to operate circuit breaker coils and to provide status feedback.
-
Industrial Machine Control: Integrated into PLC cabinets to interface 24V DC PLC digital outputs with 110V/220V AC contactor coils, motor starters, and solenoid valves.
-
Railway Signaling Systems: Employed in interlocking and trackside control cabinets to provide safe, isolated switching for signal lights, point machines, and track circuits.
-
Building Management Systems (BMS): Used to interface low-voltage building controllers with higher-power HVAC equipment such as fan coil units and damper actuators.
Comparison with Competing Products
When compared to generic interface relays from suppliers like Phoenix Contact (PLC-RSC series), Siemens (REL), or Omron (MY/GQ), the ALSTOM IR139-1 offers comparable core electrical performance. Its primary differentiator is its established specification within Alstom’s engineering standards and its proven track record in large-scale infrastructure projects, particularly in power and rail. Competing products might offer additional features like integrated surge suppression or test buttons. However, for maintaining legacy systems, fulfilling contract specifications that mandate OEM parts, or ensuring guaranteed interoperability in complex Alstom systems, the ALSTOM IR139-1 is the specified and lower-risk choice.
Selection Suggestions and Precautions
-
Verify Coil Voltage: The most critical parameter is the control coil voltage (e.g., DC or AC, 24V, 110V). Selecting an incorrect coil voltage will prevent operation or damage the relay.
-
Check Contact Rating: Ensure the relay’s contact current and voltage ratings exceed the requirements of the load you are switching, including inrush currents for inductive loads like contactor coils.
-
Confirm Contact Configuration: Verify the number and type of contacts (e.g., 2 CO) required for your circuit logic.
-
Consider the Load Type: For highly inductive loads (motors, solenoids), consider adding an external snubber circuit or verify the relay’s specified switching capacity for such loads.
-
DIN-Rail Space: Plan the panel layout accounting for the physical dimensions of the ALSTOM IR139-1 and any required terminal space.
-
Source Authenticity: To ensure safety and reliability, procure the ALSTOM IR139-1 from authorized distributors or reputable suppliers specializing in automation components to avoid counterfeit products.

IS230PCAAH1A GE
IS230SRTDH2A GE
IS230STAIH2A GE PLC
IS230STTCH2A GE PLC
IS230TCATH1A GE CPU