Description

Product Parameters
| Parameter | Specification |
|---|---|
| Model | SYNCHROTACT5 3BHB006713R0217 |
| Series | SYNCHROTACT 5 |
| Function | Automatic synchronizer / paralleling device |
| Synchronization Parameters | Voltage, frequency, and phase angle matching |
| Operating Modes | Automatic and manual synchronization |
| Outputs | Voltage and frequency raise/lower commands, breaker close command |
| Measurement Inputs | Generator and bus voltage inputs, frequency inputs |
| Communication | Serial / substation communication interfaces (per configuration) |
| Breaker Timing | Configurable breaker close time compensation |
| Mounting | Protection panel / rack installation |
| Operating Temperature | Power plant protection panel range |
| Diagnostics | Comprehensive self-diagnostics and event recording |
| Configuration | ABB synchronization engineering tools |
Advantages and Features
-
Safe, bumpless paralleling: The SYNCHROTACT5 3BHB006713R0217 matches voltage, frequency, and phase angle before issuing the close command, minimizing electrical transients and mechanical stress on the generator and breaker.
-
Automatic and manual modes: The SYNCHROTACT5 3BHB006713R0217 supports both automatic synchronization and operator-controlled manual synchronization.
-
Breaker time compensation: Configurable close time compensation in the SYNCHROTACT5 3BHB006713R0217 ensures accurate close command timing for different breaker types.
-
Comprehensive diagnostics: Self-diagnostics and event recording support fault investigation and maintenance planning.
-
Communication integration: The SYNCHROTACT5 3BHB006713R0217 supports substation communication for SCADA and remote monitoring.
-
Proven ABB platform: The SYNCHROTACT 5 series builds on decades of ABB synchronization experience.
Application Cases in Application Fields
-
Power station generators: Automatic synchronization of generators to the grid using the SYNCHROTACT5 3BHB006713R0217.
-
Combined heat and power plants: Paralleling of CHP generators with the public grid or islanded busbars.
-
Industrial captive generation: Synchronization of captive power sources in refinery, chemical, and manufacturing facilities with the SYNCHROTACT5 3BHB006713R0217.
-
Marine power systems: Paralleling of shipboard generators using the SYNCHROTACT5 3BHB006713R0217.
-
Islanded microgrids: Synchronization of multiple generation sources in isolated power systems.
Comparison with Competing Products
| Feature | ABB SYNCHROTACT5 3BHB006713R0217 | Typical Competitor A | Typical Competitor B |
|---|---|---|---|
| Synchronization parameters | Voltage, frequency, phase angle | Voltage, frequency, phase angle | Voltage, frequency |
| Automatic + manual modes | Yes | Automatic only | Yes |
| Breaker time compensation | Yes | Optional | Yes |
| Communication integration | Yes | Yes | Optional |
| Self-diagnostics | Comprehensive | Basic | Comprehensive |
| Platform maturity | Proven SYNCHROTACT 5 | Newer platform | Established platform |
The SYNCHROTACT5 3BHB006713R0217 distinguishes itself through precise three-parameter synchronization and proven reliability in demanding paralleling applications.
Selection Suggestions and Precautions
-
Confirm system voltage and frequency: Verify that the SYNCHROTACT5 3BHB006713R0217 measurement inputs match the generator and busbar voltage and frequency ratings of your system.
-
Breaker close time measurement: Measure the actual breaker close time and configure compensation in the SYNCHROTACT5 3BHB006713R0217 accordingly to ensure accurate phase-angle closing.
-
Verify communication protocol: Confirm that the SYNCHROTACT5 3BHB006713R0217 communication interface supports the protocol used by your control or SCADA system.
-
Configuration backup: Save the synchronizer configuration and settings file of the SYNCHROTACT5 3BHB006713R0217 after commissioning so it can be restored after service or replacement.
-
Testing and commissioning: Perform full synchronization testing, including dead-bus and live-bus close scenarios, before energization and record results.
-
Firmware compatibility: Confirm firmware and engineering tool versions are compatible with the SYNCHROTACT5 3BHB006713R0217 revision in your system.
-
Spare parts: Given the critical role of the SYNCHROTACT5 3BHB006713R0217 in paralleling operations, consider stocking a spare unit or ensuring rapid access to ABB service support.
-
Documentation: Retain synchronization settings, test records, and event logs for the SYNCHROTACT5 3BHB006713R0217 for compliance and maintenance purposes.