ABB AZ20 112112221112E STD

¥9,999.00

The ABB AZ20 112112221112E STD is a continuous gas analyzer from the ABB AZ20 series, designed for measuring oxygen concentration and other gas components in industrial process and combustion applications. The ABB AZ20 112112221112E STD uses a zirconia-based oxygen sensor for high-temperature combustion gas measurement, making it well suited to boiler, furnace, and kiln applications where oxygen trim and combustion efficiency control are critical. The part number 112112221112E STD encodes the specific configuration of probe length, mounting flange, sensor type, and electronics options, so the exact build must be verified against the application requirements. The analyzer communicates measurement results to the plant control system for closed-loop combustion optimization, emissions monitoring, and safety applications. Widely deployed in power generation, cement, steel, and petrochemical facilities, the ABB AZ20 112112221112E STD delivers reliable, low-maintenance oxygen measurement for continuous process monitoring.

Category:

Description

Product Parameters

Parameter Specification
Model AZ20 112112221112E STD
Brand ABB
Series AZ20 continuous gas analyzer
Measurement Principle Zirconia oxygen sensor
Measured Component Oxygen (O2) concentration
Configuration Code 112112221112E STD (probe length, flange, sensor, electronics options)
Measurement Mode In-situ / direct insertion flue gas measurement
Communication Analog and digital output to plant control system
Calibration Reference gas calibration per ABB procedure
Mounting Stack/flue flange mounting
Operating Environment High-temperature combustion gas
Design Intent Continuous oxygen measurement for combustion control and emissions monitoring

Advantages and Features

The ABB AZ20 112112221112E STD uses a zirconia sensor to provide fast, accurate oxygen measurement directly in the flue gas stream, enabling real-time combustion trim and efficiency optimization. The in-situ measurement principle of the AZ20 112112221112E STD eliminates sample transport and conditioning, reducing maintenance and response time compared with extractive analyzers. The analyzer’s heated probe and robust construction suit harsh high-temperature, high-dust environments, and the AZ20 112112221112E STD provides stable measurement with minimal drift. Diagnostic functions report sensor health and calibration status, supporting predictive maintenance. ABB’s application engineering and service network support commissioning and lifecycle management of the analyzer.

Application Cases and Fields

The ABB AZ20 112112221112E STD is commonly applied in:

  • Power plant boiler oxygen trim and combustion efficiency control

  • Cement kiln and preheater oxygen monitoring

  • Steel reheating furnace and process furnace control

  • Petrochemical fired heater combustion optimization

  • Incineration and industrial furnace emissions monitoring

In these applications, the AZ20 112112221112E STD provides continuous oxygen concentration data for combustion optimization, fuel savings, and emissions compliance.

Comparison with Competing Products

Compared with extractive oxygen analyzers, the ABB AZ20 112112221112E STD offers faster response and lower maintenance, thanks to its in-situ zirconia measurement principle. Competing in-situ oxygen probes may offer similar measurement capability but differ in probe construction, flange compatibility, and electronics integration; the AZ20 112112221112E STD benefits from ABB’s established AZ20 platform and service support. Against paramagnetic or electrochemical analyzers, the AZ20 112112221112E STD provides superior performance in high-temperature combustion gas applications. For continuous oxygen measurement in boilers and furnaces, the ABB AZ20 112112221112E STD remains a field-proven choice.

Selection Suggestions and Precautions

  • Decode the configuration code 112112221112E STD carefully to confirm probe length, flange type, sensor option, and electronics match the installation.

  • Confirm the flue gas temperature, pressure, dust loading, and stack dimensions match the AZ20 112112221112E STD probe specification.

  • Verify the required output signals and communication interfaces for integration with the plant control system.

  • Follow ABB installation and commissioning manuals for probe insertion depth, sealing, reference air supply, and calibration.

  • Procure the ABB AZ20 112112221112E STD through authorized channels to ensure authenticity, correct configuration, and warranty coverage.

  • Maintain spare sensor and probe components given the criticality of continuous combustion monitoring.

  • Perform regular calibration with reference gases and verify measurement performance against plant efficiency and emissions targets.

SIEMENS 6ES7952-1AK00-0AA0
SIEMENS 6ES7952-8LF20-0AA0
SIEMENS 6ES7972-0BA41-0XA0

Reviews

There are no reviews yet.

Be the first to review “ABB AZ20 112112221112E STD”

Your email address will not be published. Required fields are marked *

Post comment