The VIBRO-METER VM600 MPC4 is a core component of the modular VM600 platform, which is a successor and evolution of the earlier MPC4 system. The alphanumeric code PNR200-510-070-113 defines this module’s exact hardware and functional configuration. This monitoring module MPC4 integrates four independent measurement channels into a single slot within a VM600 rack. It accepts raw signals from various transducers—including eddy-current proximity probes for displacement and speed, accelerometers for vibration, and RTDs for temperature—and conditions them into standardized values. The module performs real-time processing, comparing measurements against user-defined alert and danger setpoints to initiate protective actions. The integrity of an entire machinery protection system hinges on the precision and dependability of modules like the VIBRO-METER VM600 MPC4 PNR200-510-070-113.
The VIBRO-METER MPC4 is a versatile 4-channel monitoring module that serves as a key component in machinery protection systems (MPS). The specific variant 200-510-111-035 represents a particular configuration with defined input types, output relays, and firmware. This monitoring module MPC4 accepts signals from various transducers, including proximity probes (for displacement and speed), accelerometers (for vibration), and RTDs/thermocouples (for temperature). It processes these signals to provide continuous monitoring, generate alarm and trip outputs based on user-configurable setpoints, and offer analog outputs for trend monitoring. The reliable protection of critical assets against mechanical failure heavily depends on the accuracy and reliability of devices like the VIBRO-METER MPC4 200-510-111-035.
The VIBRO-METER VMF-CPUM 200-595-046-114 is a high-performance, rack-mounted central processing unit (CPU) module designed for the VIBRO-METER VMF 200 series, a sophisticated condition monitoring and machinery protection system used for critical rotating equipment. This CPU module serves as the central brain of the monitoring rack, coordinating data acquisition from various sensor input modules (for vibration, speed, temperature, etc.), executing complex protection algorithms, managing communication with external control systems, and providing data to engineering workstations. The VIBRO-METER VMF-CPUM 200-595-046-114 is engineered for reliability in demanding environments like power generation (gas/steam turbines), oil & gas compression, and heavy industrial applications, where it plays a vital role in preventing catastrophic machinery failures by providing early warning and trip signals based on real-time analysis of machine health.
The VIBRO-METER VM600 204-040-100-012 is a high-performance rack-mounted I/O module from the VM600 Machinery Protection System (MPS) family. This specific model is a Triple Channel DC Input Card, designed to interface with low-level DC voltage signals from proximity probes, speed sensors, and other transducers used for monitoring rotating machinery. The primary role of the VM600 204-040-100-012 is to condition, digitize, and transmit critical vibration, speed, and position data from up to three independent channels to the system’s Central Processing Unit (CPU) for continuous monitoring and protection. Integrating the Vibro-Meter VM600 204-040-100-012 into a protection rack provides a reliable and precise front-end for safeguarding turbines, compressors, and other high-value assets.
The VIBRO METER VM600 MPC4 PNR200-510-070-113 is a sophisticated and highly specialized module for machinery condition monitoring and protection, not a traditional PLC component, but an integral part of a supervisory control and safety system for critical rotating assets. This unit is a specific configuration of the VIBRO METER VM600 system, which is a leading modular platform for continuous monitoring of vibration, speed, temperature, and other dynamic parameters in turbines, compressors, pumps, and generators. The MPC4 designation indicates it is a Monitoring & Protection Card, a core processing unit that acquires data from sensors, executes protection algorithms, and drives relay outputs. The suffix PNR200-510-070-113 defines its precise hardware and firmware configuration, including input types, relay configurations, and communication options. The primary function of the VIBRO METER VM600 MPC4 is to protect high-value machinery from catastrophic damage by detecting abnormal conditions like excessive vibration, imbalance, misalignment, and bearing wear, and initiating alarms or trips. Integrating this module into a plant’s control architecture provides a vital layer of asset protection that operates in conjunction with, but often independently from, the main process PLC or DCS.
The VIBRO-METER VMF-MPC4 200-510-111-034 200-510-070-113, detailed further here, is a sophisticated, multi-channel condition monitoring module designed for the continuous protection and analysis of critical rotating machinery. This system acts as an intelligent front-end data acquisition and processing unit, bridging the gap between vibration, speed, and process sensors and a plant’s higher-level control (PLC/DCS) or dedicated monitoring system. The primary function of the VIBRO-METER VMF-MPC4 is to acquire raw signals from transducers, perform real-time signal processing (like FFT analysis), and generate both protective alarm/trip outputs and detailed diagnostic data. It serves as the dedicated “guardian” for turbomachinery such as gas turbines, steam turbines, and compressors, providing the immediate reaction needed to prevent catastrophic failure while feeding information for predictive maintenance. For reliability engineers and control system specialists, integrating a robust system like the VIBRO-METER VMF-MPC4 is essential for achieving both operational safety and asset optimization.
The key technical specifications of the VM600 RPS6U include:
Parameter
Value
Input Voltage
100-240 VAC
Output Voltage
24 VDC
Output Current
Up to 6A
Power Rating
144W
Interface Type
Hot-swappable
Compatibility
Schneider Electric PLCs
3. Advantages and Features
The VM600 RPS6U stands out for its high reliability, redundancy, and ease of integration. With a mean time between failures (MTBF) exceeding industry standards, it ensures minimal downtime and maximum system uptime. The unit’s hot-swappable feature allows for seamless replacement without disrupting system operation, further enhancing reliability. Additionally, its compact footprint and modular design facilitate easy installation and maintenance, reducing overall lifecycle costs.
VIBRO-METER VM600 CPUM 200-595-067-114 is an input/output module that works with the VM600 System Rack (ABE04x). It can be used either alone or as a pair with associated IOCN cards, depending on application/system requirements .
function :
The CPUM card acts as the “rack controller”, establishing the Ethernet link between the rack and the computer running the VM600 MPSx package (MPS1 or MPS2). Its highly integrated design makes it easy to integrate into existing systems, improving system reliability and efficiency .
This model belongs to the mechanical monitoring system, the specific model is VIBRO-METER VM600 IOC16T, including the numbers 200-565-000-013 and 200-565-101-013.
Weight :
The exact weight of the model is not directly mentioned in the search results, but similar products, such as the VIBRO-METER VM600 monitoring system, have a weight information of 2KG.
The model is VIBRA-Meter VM600 series IOC4T input/output card, which belongs to the DCS (Distributed control system) component of industrial control system and equipment .
Weight :
The exact weight is not given directly, but you can see that similar models (such as the Vibro-meter 200-566-000-012 200-566-101-012 VM600 board) weigh 1.6kg, and the IOC4T card may weigh similar to .
Vm600 rps6u 200-582-200-011card is a high quality vibrometer designed for accurate and reliable measurements. It has expanded functions and parameters that make it suitable for different applications.
Product parameters:
– model: vm600 rps6u 200-582-200-011card
– measuring range: 0-2000 mm/s
– frequency range: 10 hz – 10 KHZ
Accuracy: + -5 per cent
– power supply: battery 9b