The Johnson Controls MS-NAE5510-2 is a Network Automation Engine (NAE) from the Johnson Controls Metasys building automation system portfolio, designed to supervise and coordinate HVAC, lighting, and other building systems within a facility. The MS-NAE5510-2 acts as a supervisory controller, managing field controllers and devices over building networks, hosting scheduling and alarm functions, and providing a user interface for building operators. Engineered for reliable continuous operation in mechanical rooms and building automation cabinets, the MS-NAE5510-2 supports the integration of multiple field buses and network protocols used in commercial buildings. The “-2” suffix indicates a specific configuration or revision level, so customers should verify that this variant matches their system requirements. For facilities maintaining Metasys installations, the MS-NAE5510-2 serves as an important spare, helping preserve building automation availability and avoid disruption to critical building services. Its place within the established Metasys architecture ensures predictable serviceability and documentation support.
Model: MS-NAE5510-3
Brand: Johnson Controls
Processor type: High performance microprocessor
Communication protocols: BACnet, LonWorks, Modbus, etc
Power Supply: 24 VDC
Power consumption: 25 W
Specifications:
Size: 3U PXI module
Weight: 0.5kg
Operating temperature: 0°C to 60°C
Operating humidity: 5% to 95% (non-condensing)
Supported features: schedules, alerts, trends, data logging, etc
Power Supply: Typically operates on 24VAC with a range of 20-30VAC.
Power Frequency: Standard 50/60Hz.
Power Consumption: 50VA.
Memory: 4GB of flash memory and 1GB of SDRAM.
Ports and Interfaces: Supports Ethernet, RS-485, RS-232, and USB ports.
Ethernet Port: Supports speeds up to 1,000Mbps.
Operating Temperature: -40℃ to 85℃.
Storage Temperature: -55℃ to 125℃.
Model : MS-NAE5510-3
Dimensions : 222 mm x 111 mm x 44 mm (8.75 “x 4.37” x 1.75 “)
Weight : One says 1.13 kg(2.49 LBS)1, the other says 2kg
Power supply : 24 VDC
power consumption : typical value 15 watts, maximum 25 watts
communication protocol : BACnet/IP, BACnet MS/TP, LonWorks, etc
point capacity : The maximum support 30,720 points
Storage capacity : 2 GB non-volatile flash
Power Supply: 24VAC or 24VDC, typical power consumption 15 watts, maximum power consumption 25 watts.
Current: The current range may vary according to the specific application, there is a current value of 100-400A mentioned, but it should be noted that this may be confused with other products.
Storage capacity: 2 GB of non-volatile flash.
Point capacity: Maximum support 30,720 points.
specification
Operating system: PLC system.
System function: Automatic.
System environment: normal temperature.
System capability: Powerful.
Johnson ms-nae5510-2 SCR is a high-performance solid-state relay designed for a variety of industrial applications. It provides reliable switching and control of ac loads.
Product parameters:
– input voltage: 3-32 v dc
– output voltage: 24-280 v
– voltage: 10a
– control method: zero transition
– type of installation: panel unit
– operating temperature: -40 c to 80 c
Johnson ms-nae4510 PLC is a high-performance programmable logic controller that provides accurate control and monitoring capabilities. It has a user-friendly interface and supports various communication protocols.
Product parameters (s)
– input voltage: 24v dc
– output voltage: 24v dc
– communication interface: Ethernet, rs485
– memory capacity: 16mb
– operating temperature: – 10 to 60 degrees
– product description: Johnson ms-nae3514 plcmodule
High-performance programmable logic controller designed for industrial automation. It offers enhanced control and monitoring capabilities to optimize the efficiency and reliability of processes.
– product parameters:
– input voltage: 24v dc
– output voltage: 24v dc
– communication interface: Ethernet, rs485
– operating temperature: – 10 to 60 degrees
– dimensions: 100 mm x 120 mm x 50 mm
– model: ms-nae5510-2
– size: standard
– power supply: 24v dc
– connection: Ethernet, rs485
– inputs: 8 digital inputs, 4 analog inputs
– outputs: 4 relays
– operating temperature: -40 c to 85 c
– installation: din rail