Showing 1–12 of 428 results

HIMA F7126

¥2,599.00

Product Parameters

  • Module Type: Safety System Power Supply Module.

  • Input Voltage: Typically accepts a wide-range AC or DC input, such as 85-264V AC or 88-300V DC, to accommodate various global plant power standards.

  • Output Voltage: Provides a stabilized and filtered 24V DC output to power the HIQuad backplane and all installed modules.

  • Output Power/Current: Rated for a specific power output (e.g., 240W, 480W) to support fully populated controller chassis with all modules under load.

  • Redundancy Support: The HIMA F7126 is designed to be used in redundant (1oo2) configurations. Two modules can be installed in a single chassis, with one actively powering the system and the other in hot standby. Automatic switchover occurs upon failure of the active unit.

  • Diagnostics & Monitoring: Features comprehensive monitoring of:

    • Input voltage presence and status.

    • Output voltage level and stability.

    • Module temperature.

    • Load sharing status (in redundant mode).

    • Failure of the active unit.

    • Status is communicated via relay contacts (e.g., “Power OK”, “Failure”) and/or over the system backplane to the CPU.

  • Protection Features: Includes standard protections such as overload protectionshort-circuit protection, and overtemperature protection to safeguard both the supply and the downstream controller.

  • Efficiency & Cooling: High efficiency design to minimize heat generation. May include integrated fans or be convection cooled, depending on the power rating.

  • Certifications: Certified for use in safety-related systems and complies with relevant EMC and safety standards (e.g., ATEX/IECEx for certain versions).

  • Form Factor: A slot-in module designed for the HIQuad system chassis.

HIMA F7101

¥999.00

Detailed Product Parameters

  • System Compatibility: HIMA F3x Series I/O System, compatible with HIMA safety controllers.

  • Function: Digital Output Module with Forced-Guided Relays.

  • Output Type: Dry contact relay outputs (volt-free).

  • Number of Channels: Typically 4 or 8 channels per module.

  • Contact Rating: Typically 2A @ 230V AC or 24V DC, suitable for direct switching of solenoids and small contactors.

  • Diagnostic Coverage (SFF): High, suitable for Safety Integrity Level (SIL) 3 applications as per IEC 61508.

  • Key Safety Feature: Incorporates mechanically forced-guided (or “positively driven”) relays. The contacts are mechanically linked so that if a normally-open (NO) contact welds shut, the corresponding normally-closed (NC) diagnostic contact is guaranteed to remain open, allowing the module’s internal circuitry to detect the fault.

  • Diagnostics: Continuous monitoring for relay coil faults, contact welding (via the forced-guided principle), wire break on the output circuit, and internal module health.

  • Certifications: Compliant with IEC 61508, IEC 61131-2, and other relevant standards for functional safety.

HIMA F6705

¥999.00

Product Parameters

  • Module Type: Communication / Interface Module for Safety Systems.

  • Compatible Systems: Designed for integration with HIMA safety controllers such as those in the HIMax or HIQuad series.

  • Primary Function: Acts as a protocol gateway and data concentrator. It reads data from the safety controller’s backplane and makes it available to external systems via standard industrial protocols.

  • Supported Communication Protocols: Commonly supports widely used protocols for integration, which may include:

    • Modbus TCP/IP (for Ethernet-based SCADA, DCS, and HMI connectivity).

    • Modbus RTU (for serial communication).

    • OPC (DA/UA) for connection to historians and advanced visualization systems.

    • HIMA’s proprietary protocols for peer-to-peer communication between safety systems.

  • Data Mapping: Allows configuration of data points (process values, diagnostics, system status) from the safety controller to be mapped to registers or tags in the external protocol.

  • Interface Ports: Typically features physical ports such as RJ45 Ethernet and/or serial ports (RS-232/485).

  • Safety Integrity: While not executing safety logic itself, the module is designed for use in safety systems. It operates in the non-safety domain but is built to high reliability standards to ensure communication availability without affecting the safe operation of the controller.

  • Diagnostics: Includes self-diagnostic capabilities and status indicators (LEDs) to monitor communication link health and module operation.

  • Configuration: Configured using HIMA’s engineering software suite (e.g., Safety-Editor or dedicated configurators).

HIMA F6220

¥5,249.00

Detailed Product Parameters

  • System Compatibility: HIMA F3x Series I/O System, compatible with HIMA safety controllers like HIQuad X, HIMax, etc.

  • Function: Digital Input Module for Safety Applications.

  • Number of Channels: Typically 8 or 16 channels per module (varies by specific sub-variant).

  • Input Type: Configurable for NAMUR sensors (IEC 60947-5-6) or dry contact (volt-free) signals.

  • Diagnostic Coverage (SFF): High (>90%), supporting use in Safety Integrity Level (SIL) 3 applications as per IEC 61508.

  • Diagnostics: Includes continuous monitoring for wire breaks, short-circuits to ground/power, cross-channel faults, and internal module faults.

  • Safe State Definition: Configurable per channel for fault behavior (e.g., can be set to 0 or 1 in case of a detected fault).

  • Certifications: Compliant with major international standards including IEC 61508, IEC 61131-2, and ATEX for use in hazardous areas (with appropriate barriers).

HIMA Z1001

¥5,299.00

Product Parameters

  • Module Type: Safety CPU module for HIMax system.

  • Safety Standards: Certified according to IEC 61508:2010 and IEC 61511:2016 for use in SIL 3 and SIL 4 applications. Also certified by TÜV and other global agencies.

  • Architecture: Based on a single-channel architecture with extensive internal self-testing and diagnostics. The HIMax system achieves high safety through advanced diagnostics rather than hardware redundancy at the CPU level, though the system supports redundant CPU configurations for higher availability.

  • Processor & Performance: Features a powerful microprocessor optimized for deterministic execution of safety logic. It provides predictable scan times suitable for fast-acting safety functions.

  • Memory: Equipped with fault-secure memory (RAM and Flash) with error detection and correction (ECC). The memory stores the safety application, operating system, and configuration data.

  • Diagnostics (Key Feature): Incorporates Continuous Functional Monitoring (CFM). This includes extensive periodic and non-periodic self-tests of the CPU, memory, and internal buses during runtime to detect over 99% of dangerous failures.

  • Communication Interfaces:

    • System Bus: Connects to the HIMax backplane for communication with I/O and communication modules.

    • Ethernet Port(s): For engineering (programming/troubleshooting), connection to HMIs, and system networking (e.g., via HIMA’s SAFEmine or other protocols).

  • Programming: Programmed using HIMA’s Safety-oriented Programming Languages, which are constrained versions of IEC 61131-3 (like F-FBD, F-LD, F-ST) within the Safety-Editor engineering software to prevent unsafe coding practices.

  • Operating Temperature: Designed for industrial control panel environments, typically 0°C to 60°C.

Sale!

HIMA F3236

¥16,529.00

The HIMA F3236 is a 16 – channel digital input module designed for safety – related applications2. It is mainly used to process and monitor digital input signals in industrial systems2. The module has the advantages of high accuracy, wide compatibility and flexible configuration

Sale!

HIMA F6217

¥15,284.00

The HIMA F6217 is an 8 – channel analog input module designed for industrial automation systems2. It interfaces seamlessly with a wide range of analog sensors and transmitters, effectively converting input signals such as current or voltage into digital data for further processing within the HIMA safety controller.

Sale!

HIMA F6217

¥24,615.00

The HIMA F6217 is an 8 – channel analog input module designed for safety – related applications1. It interfaces with a variety of analog sensors and transmitters, converting input signals like current (0/4 – 20 mA) and voltage (0 – 5/10 V) into digital data for processing within the HIMA safety controller.

Sale!

HIMA F7126

¥16,542.00

The HIMA F7126 is a digital input module widely recognized for its reliability and performance in safety – critical industrial automation systems. It serves as a vital component for receiving and processing digital signals from various field devices.

Sale!

HIMA F8652X

¥13,428.00

Parameters and Specifications:

  • Processor: Based on Arm Cortex TDA4VM processor (for the 984865265 model)
  • Memory:
    • Flash EPROM for Operating System: 1 MB
    • Flash EPROM for User Program: 512 kByte
    • Data Memory (sRAM): 256 kByte
  • Interfaces:
    • 2 Serial Interfaces: RS 485
    • Other communication interfaces (e.g., Ethernet, Profibus) may be available
  • Operating Temperature: -20℃ to 60℃
Sale!

HIMA F8627X

¥12,405.00

Parameters and specifications:

Series: F8627X series
Usage: Designed for industrial automation for data communication and network connectivity
Operating voltage: The specific value may vary according to the application scenario, such as 14V for a product
Output voltage and temperature: can be set individually for each thermocouple (temperature detector) channel
Supported protocols: including Modbus, Profibus, Profinet, and EtherNet communication protocols such as EtherNet/IP

Sale!

HIMA H7506 992750602

¥16,529.00

Parameters and Specifications:

  • Model: H7506 992750602
  • Manufacturer: HIMA (HIMA Paul Hildebrandt GmbH)
  • Type: Not specified, but likely a part of a safety system or automation system1
  • Voltage: 24V2

Dimensions and Weight:

  • Exact Dimensions and Weight: Not provided in the search results.