Description

Product Parameters
| Parameter | Specification |
|---|---|
| Model | 9907-1200 |
| Series | 9907 |
| Function | Digital governor for turbines and prime movers |
| Speed Input | Magnetic pickup and proximity probe inputs |
| Control Modes | Isochronous and droop control |
| Actuator Output | Configurable current output for steam/fuel valve actuators |
| Discrete I/O | Configurable discrete inputs and relay outputs |
| Analog I/O | Configurable analog inputs for load and auxiliary signals |
| Communication | Serial communication port for configuration and monitoring |
| Power Supply | 24 V DC nominal (per nameplate rating) |
| Mounting | Panel or cabinet mounting |
| Operating Temperature | Industrial range for plant cabinets |
| Isolation | Galvanic isolation on I/O channels |
| Configuration | WOODWARD service tool / PC-based configuration |
| Diagnostics | Status indicators and configurable fault annunciation |
Advantages and Features
-
Turbine-specific control: The 9907-1200 is designed specifically for turbine governing, with control algorithms tuned for steam and gas turbine dynamics.
-
Multiple control modes: Isochronous and droop modes allow the 9907-1200 to serve both islanded and paralleled generation applications.
-
Flexible I/O configuration: Configurable analog and discrete channels adapt the 9907-1200 to different turbine and switchgear arrangements.
-
Robust electrical isolation: Galvanically isolated I/O protects the 9907-1200 from ground loops and electrical noise common in power plant environments.
-
Proven WOODWARD platform: The 9907 series builds on WOODWARD’s long experience in turbine governing and power generation control.
-
Comprehensive protection logic: Configurable overspeed, underspeed, and auxiliary trip functions protect the turbine and generator.
Application Cases in Application Fields
-
Steam turbine generators: Speed governing and load control for industrial and utility steam turbine packages using the 9907-1200.
-
Gas turbine packages: Speed control and synchronization for small industrial gas turbine-generator sets with the 9907-1200.
-
Cogeneration plants: Load control between turbines and other prime movers in combined heat and power installations.
-
Industrial drive turbines: Governing of mechanical drive turbines in process plants.
-
Islanded power systems: Frequency and load control for isolated generation systems using the 9907-1200.
Comparison with Competing Products
| Feature | WOODWARD 9907-1200 | Typical Competitor A | Typical Competitor B |
|---|---|---|---|
| Turbine-specific algorithms | Yes | General-purpose governor | Yes |
| Control modes | Isochronous, droop | Isochronous, droop | Isochronous, droop, load share |
| I/O configurability | Flexible analog + discrete | Fixed I/O | Partially configurable |
| Galvanic isolation | Yes, on I/O channels | Partial | Yes |
| Protection logic | Configurable trips | Basic overspeed | Basic overspeed |
| Configuration tool | WOODWARD service tool | Vendor-specific | Vendor-specific |
The 9907-1200 distinguishes itself through turbine-specific control algorithms and a flexible, isolated I/O mix suited to demanding power plant environments.
Selection Suggestions and Precautions
-
Confirm actuator compatibility: Verify that the actuator output of the 9907-1200 matches the current and voltage requirements of your steam or fuel valve actuator.
-
Verify power supply rating: Check the nameplate for the exact supply voltage and tolerance of the 9907-1200 and provide a regulated, filtered supply.
-
Speed signal quality: Ensure the magnetic pickup or proximity probe mounting, tooth count, and cable shielding meet WOODWARD requirements to avoid speed signal noise on the 9907-1200.
-
Configuration backup: Save the configuration file of the 9907-1200 after commissioning so it can be restored after service or replacement.
-
Protection setpoint review: Validate all overspeed, underspeed, and trip setpoints against turbine manufacturer limits during commissioning.
-
Steam valve characterization: Confirm the valve stroke and gain settings match the 9907 configuration for stable control.
-
Spare parts: Given the specialized configuration of the 9907-1200, consider stocking a spare unit or ensuring access to WOODWARD service support for critical installations.
-
Firmware and tool version: Confirm the service tool version is compatible with the firmware revision of the 9907-1200 before deployment.



Reviews