Input Type: Thermocouple J, K, T (default)
-
Channels: 16 differential (fixed, non-expandable)
-
Resolution: 14-bit ADC, ±0.1°C accuracy at 25°C ambient
-
Cold Junction: Single onboard sensor (non-redundant in this variant)
-
Isolation: 1500V RMS channel-to-backplane (lower than HFPB variants)
-
Power: +5V DC @ 1.0A only (no +15V required – differs from B variant)
-
Scan Rate: 250ms per channel (slower than HFPC’s typical 150ms in newer firmware)
-
Mounting: 6U VME Eurocard, single-slot
Advantages & Features
-
Lower power consumption (no +15V rail needed) – ideal for legacy cabinets with limited supply
-
Simplified cold-junction design reduces component failure points
-
Front-panel LEDs for channel status and open-circuit detection
-
Compatible with Mark IV backplanes (not VIe without adapter)
-
Interchangeable with DS3800HFPB in most applications (check pinout first)
Application Cases
-
Exhaust temperature monitoring in Frame 6B gas turbines
-
Bearing temperature tracking in Frame 7EA steam turbines
-
Retrofit replacements for obsolete DS3800H single-ended boards
-
Power plants transitioning from Mark IV to partial Mark VIe upgrades
Competitor Comparison
-
vs. DS3800HFPB (B variant): Lower isolation (1500V vs. 2500V) and no redundant CJC, but no +15V requirement
-
vs. DS3800HFPB1F1E (coated variant): No conformal coating – less suitable for humid/corrosive sites
-
vs. ABB TB711 : More cost-effective, but slower scan rate (250ms vs. 150ms)
-
vs. Siemens 7MH410 : Simpler to configure (jumper-based vs. software), but lacks diagnostics
-
vs. Woodward 8440-2015 : Better long-term stability, but limited to J/K/T types only
Selection Suggestions
-
Verify your backplane does not provide +15V – if it does, consider HFPB variant instead
-
Confirm thermocouple type (J/K/T) matches your sensors – no E/S support
-
Check if you need redundant cold-junction – if yes, choose HFPB not HFPC
-
Ensure scan rate (250ms) meets your turbine’s alarm response requirements
-
Purchase with a 12-month warranty for used/refurbished units due to age
Precautions
-
Critical: Do not interchange with HFPB without verifying front connector pinout – pin assignments differ
-
Use thermocouple-grade extension wire – copper wire will cause inaccurate readings
-
Allow 30-minute warm-up before calibration or commissioning
-
Do not hot-swap – the backplane requires power-off for insertion/removal
-
Store in ESD-safe packaging – the edge connector is sensitive to static discharge
-
Periodically check cold-junction sensor drift every 2 years (calibrate against ice bath)
-
If replacing a failed unit, verify firmware version matches turbine control logic (older revisions may have different linearization tables)