ICS TRIPLEX T8314

¥5,299.00

Product Parameters

  • Module Type: Triple Modular Redundant (TMR) Digital Input Module.

  • Input Type: Typically designed for dry contact inputs (e.g., from switches, relay contacts). The module provides a wetting voltage (often 24V DC) to detect the open/closed state of the field contact.

  • Input Channels: Contains multiple independent input channels per module (e.g., 8, 16, or 32 channels). Each channel processes a single field contact.

  • Redundancy Architecture: Employs true hardware TMR at the channel level. Each field input is connected to three identical, but electrically isolated, input circuits within the module. These three circuits provide independent readings to the three controller channels.

  • Fault Tolerance: Can tolerate the failure of any one of the three internal input circuits for a given channel without corrupting the input data. The TMR controller performs a 2-out-of-3 vote on the three signals to determine the true state of the field contact.

  • Isolation: Provides high-grade channel-to-channel isolation and field-to-system isolation. This prevents ground loops, noise interference, and prevents a fault on one input or field wire from affecting others.

  • Diagnostics: Includes continuous online diagnostics that monitor the health of the internal power supplies, each of the three input circuits per channel, and the overall module logic. Faults are reported in detail to the main TMR controller.

  • Response Time: Very fast input response and filtering, suitable for high-speed safety interlock logic.

  • Safety Certification: Certified for use in Safety Integrity Level 3 (SIL 3) applications per IEC 61508/61511 standards.

  • Form Factor: A single-slot module designed for installation in the Trusted system’s main or expansion I/O chassis.

Category:

Description

Product Overview

The ICS TRIPLEX T8314 is a specialized digital input (DI) module engineered for the Trusted® TMR (Triple Modular Redundant) System, a premier fault-tolerant platform for safety and critical control. This module serves as the primary interface for reading discrete (on/off) signals from the field—such as switch contacts, relay outputs, or solenoid valve feedback—into the high-integrity TMR controller. The ICS TRIPLEX T8314 is designed to uphold the system’s core principles of triple redundancy, fault tolerance, and diagnostic coverage right at the point of signal acquisition. Its primary function is to receive a single field contact input, condition and isolate it, and then present three independent, validated digital signals (one for each of the TMR controller’s channels) for voting and logic processing. Implementing the genuine ICS TRIPLEX T8314 is fundamental for ensuring the reliability and accuracy of safety-critical shutdown and interlock logic based on field device status.

Product Parameters

  • Module Type: Triple Modular Redundant (TMR) Digital Input Module.

  • Input Type: Typically designed for dry contact inputs (e.g., from switches, relay contacts). The module provides a wetting voltage (often 24V DC) to detect the open/closed state of the field contact.

  • Input Channels: Contains multiple independent input channels per module (e.g., 8, 16, or 32 channels). Each channel processes a single field contact.

  • Redundancy Architecture: Employs true hardware TMR at the channel level. Each field input is connected to three identical, but electrically isolated, input circuits within the module. These three circuits provide independent readings to the three controller channels.

  • Fault Tolerance: Can tolerate the failure of any one of the three internal input circuits for a given channel without corrupting the input data. The TMR controller performs a 2-out-of-3 vote on the three signals to determine the true state of the field contact.

  • Isolation: Provides high-grade channel-to-channel isolation and field-to-system isolation. This prevents ground loops, noise interference, and prevents a fault on one input or field wire from affecting others.

  • Diagnostics: Includes continuous online diagnostics that monitor the health of the internal power supplies, each of the three input circuits per channel, and the overall module logic. Faults are reported in detail to the main TMR controller.

  • Response Time: Very fast input response and filtering, suitable for high-speed safety interlock logic.

  • Safety Certification: Certified for use in Safety Integrity Level 3 (SIL 3) applications per IEC 61508/61511 standards.

  • Form Factor: A single-slot module designed for installation in the Trusted system’s main or expansion I/O chassis.

Advantages and Features

  1. Highest Signal Integrity and Fault Tolerance: The defining advantage of the ICS TRIPLEX T8314 is its triple-redundant sensing of each field contact. This hardware-based TMR design ensures that a single point of failure within the input circuitry—such as a failed opto-isolator or component—cannot cause a misrepresentation of the field state to the safety controller, eliminating a major source of spurious trips.

  2. Robust Noise Immunity and Isolation: The module’s design includes heavy filtering and high-grade isolation on all three signal paths. This makes it exceptionally resistant to electromagnetic interference (EMI), ground shifts, and transient noise commonly found in industrial environments, ensuring stable and accurate signal reading.

  3. Comprehensive Diagnostic Coverage: The module performs extensive self-checks that go beyond simple “module fail” detection. It can identify faults within a specific channel’s circuitry (e.g., “Channel A, Input 5 circuit fault”), enabling predictive maintenance. This allows for the planning of module replacement before a second fault could compromise the TMR voting.

  4. Maintains System Availability: Because a fault in one of the three internal input paths does not cause a channel failure (the other two healthy paths continue to provide valid data for voting), the input function remains fully operational. This design maximizes the availability of the safety function, which is as critical as its reliability.

  5. Seamless Trusted System Integration: The ICS TRIPLEX T8314 is natively designed for the Trusted backplane and diagnostic framework. Configuration, status monitoring, and fault reporting are fully integrated into the Trusted engineering and runtime environment, simplifying system design and operation.

Application Fields and Case Studies

Application Fields:
Deployed in high-hazard industries where the status of field devices must be read with utmost reliability to trigger safety actions.

  • Oil & Gas: Reading Emergency Shutdown (ESD) pushbutton status, pressure switch (PSHH, PSLL) contacts, valve limit switch (open/close) feedback, and fire & gas detector alarms.

  • Chemical/Petrochemical: Monitoring burner flame detectorshigh-level switches on reactors, and safety relay contacts in interlock chains.

  • Power Generation: Reading turbine overspeed switch contacts, breaker auxiliary contacts, and critical pump vibration switch status.

  • Rail/Transportation: Reading vital track side signals and interlocking system contacts.

Application Case:
On an offshore oil platform, a high-pressure safety switch on a gas compressor discharge line is wired to a ICS TRIPLEX T8314 digital input module. This switch is a primary input to the ESD system. During a severe storm, moisture ingress causes a minor internal short in the “Channel B” sensing circuit for that specific input point within the T8314 module. The module’s diagnostics immediately report a “degraded input circuit” fault for that channel. However, because the input is triplicated, the TMR controller continues to receive valid signals from the fully functional Channel A and Channel C circuits. The 2-out-of-3 voting logic correctly interprets the field switch’s state (still closed/normal), and no spurious shutdown is triggered. The maintenance team is alerted to the degraded module but can schedule its replacement during calm weather, avoiding an unnecessary and hazardous production shutdown.

Comparison with Competing Products

Feature ICS TRIPLEX T8314 (TMR Hardware Redundant DI) Dual Redundant (1oo2D) Safety DI Module Single-Channel High-Integrity DI Module Standard PLC DI Module
Redundancy & Fault Tolerance Highest (TMR). Tolerates any single fault within the module’s input circuitry per channel without data corruption. High (Dual). Tolerates failure of one entire module. A fault within a single channel’s circuit may cause a switchover or alarm. None. A single point of failure. Any internal fault can lead to erroneous data. None. For basic control only.
Noise Immunity & Diagnostics Exceptional. High isolation and filtering on three paths. Diagnostics to component level. Very Good. Good isolation and diagnostics, typically to the module level. Good. Standard isolation and diagnostics. Basic. Minimal diagnostics and isolation.
Availability & Trip Avoidance Extremely High. Internal circuit faults do not cause input state changes, preventing nuisance trips. High. Module failure causes a switchover, a disturbance but maintains function. Risk of trip from internal channel fault is present. Low. Any internal fault can cause a false trip. N/A (Non-Safety).
Cost & Complexity Highest. Premium for ultimate diagnostic depth and fault tolerance within the module itself. High. Significant investment for high-integrity safety. Moderate. For lower SIL or non-critical applications. Lowest.

Selection Suggestions and Precautions

  1. Define Safety Requirements: Select the ICS TRIPLEX T8314 for inputs that are part of a SIL 2 or SIL 3 safety function where both reliability and high availability (avoiding spurious trips) are critical. Use standard or single-channel modules for non-critical status inputs.

  2. Proper Field Wiring: Use the correct wire gauge and ensure terminations are tight. For dry contact inputs, the module supplies the wetting voltage; do not apply an external voltage. Adhere to separation standards, keeping these safety input wires away from power cables to minimize noise induction.

  3. Configure Input Filtering Correctly: Use the module’s configurable debounce/filter time to match the characteristic of the field device (e.g., a mechanical switch needs more filtering than a solid-state relay). This prevents contact bounce from being seen as multiple state changes.

  4. Actively Monitor Diagnostics: Do not ignore diagnostic alarms. Configure the system to annunciate module faults (e.g., “T8314 Chassis X, Slot Y – Degraded Input Channel”) prominently. A degraded TMR input still functions but has reduced fault tolerance until repaired.

  5. Plan for Online Maintenance: Keep a qualified spare module in stock. The TMR architecture allows for the online replacement of a faulted T8314. Ensure maintenance personnel are trained on the specific procedures for safely removing and installing modules in the Trusted system.

3HAC12924-1
0010-09750 PLC
E1421B PLC
34980A
REF615 PLC
A06B-6111-H006#H550 PLC
A06B-6110-H006 PLC
YPQ110A
DS1405012-E5 PL