GE UR8AH

¥999.00

GE UR8AH is a CT/VT (Current Transformer/Voltage Transformer) module designed for GE Multilin Universal Relays, serving as a critical signal conditioning component for power system protection and monitoring. It scales high-voltage/current power system signals to measurable levels for UR series relays, integrating 3 phase CTs (1A/5A), 1 ground CT (1A/5A), and 4 VTs (120V/240V) with Class 0.5 CT accuracy and Class 1 VT accuracy. GE UR8AH supports up to 24 configurable analog CT/VT signals, configurable via EnerVista UR software, and requires secondary winding grounding for operator safety. Compatible with UR-9A/UR-9C/UR-9D CPU modules and firmware 3.5x or earlier, GE UR8AH enables precise fault detection, overcurrent/overvoltage protection, and seamless integration with SCADA/DCS via Modbus RTU/DNP3. It operates in -40°C to +85°C harsh environments, making GE UR8AH ideal for feeders, transformers, generators, and substation automation requiring reliable signal scaling and protection coordination.

Category:

Description

Product Description

GE UR8AH is a CT/VT (Current Transformer/Voltage Transformer) module designed for GE Multilin Universal Relays, serving as a critical signal conditioning component for power system protection and monitoring. It scales high-voltage/current power system signals to measurable levels for UR series relays, integrating 3 phase CTs (1A/5A), 1 ground CT (1A/5A), and 4 VTs (120V/240V) with Class 0.5 CT accuracy and Class 1 VT accuracy. GE UR8AH supports up to 24 configurable analog CT/VT signals, configurable via EnerVista UR software, and requires secondary winding grounding for operator safety. Compatible with UR-9A/UR-9C/UR-9D CPU modules and firmware 3.5x or earlier, GE UR8AH enables precise fault detection, overcurrent/overvoltage protection, and seamless integration with SCADA/DCS via Modbus RTU/DNP3. It operates in -40°C to +85°C harsh environments, making GE UR8AH ideal for feeders, transformers, generators, and substation automation requiring reliable signal scaling and protection coordination.

Product Parameters

  • Module Type: CT/VT signal conditioning module (GE Multilin Universal Relays series)
  • Core Function: Power signal scaling, CT/VT signal conditioning, fault detection, protection coordination, software configuration
  • Current Inputs: 3 phase CTs (1A/5A selectable); 1 ground CT (1A/5A); Class 0.5 accuracy; 5VA burden per CT
  • Voltage Inputs: 4 VTs (120V/240V selectable); Class 1 accuracy; 5VA burden per VT
  • Signal Capacity: Up to 24 configurable analog CT/VT signals; secondary winding grounding required
  • Compatibility: UR-9A/UR-9C/UR-9D CPU modules; firmware 3.5x or earlier; EnerVista UR software
  • Communication: Supports Modbus RTU, DNP3 for SCADA/DCS integration
  • Mechanical & Environmental: DIN rail mounting; -40°C to +85°C operating temp; 5%-95% non-condensing RH; ~0.3kg; 170mm×100mm×45mm
  • Power: 24VDC/0.5A (18-30VDC tolerance); typical power consumption ≤3W

Advantages and Features

  1. Precision Signal Scaling

    GE UR8AH delivers Class 0.5 CT and Class 1 VT accuracy, ensuring reliable power signal measurement for protection and control.

  2. Enhanced Operator Safety

    Secondary winding grounding and fault detection capabilities of GE UR8AH minimize electrical hazards and unsafe system conditions.

  3. Flexible Configuration

    EnerVista UR software support lets GE UR8AH adapt to diverse CT/VT ratios and protection schemes without hardware changes.

  4. Broad System Compatibility

    Works with legacy UR-9A/UR-9C/UR-9D CPUs, making GE UR8AH ideal for retrofits and extending system lifecycle.

  5. Harsh Environment Reliability

    Wide temperature range (-40°C to +85°C) guarantees GE UR8AH performs reliably in outdoor substations and industrial power sites.

Application Cases in Application Fields

  • Transformer ProtectionGE UR8AH scaled 11kV/400V transformer signals, enabling overcurrent/undervoltage protection and reducing fault response time by 50%.
  • Generator Control: It coordinated CT/VT signals for a 5MW generator, supporting load shedding and voltage regulation via Modbus RTU to SCADA.
  • Substation AutomationGE UR8AH integrated 20 feeders, providing real-time current/voltage data for DNP3-based grid monitoring and remote control.
  • Industrial Feeder Protection: It protected 10kV feeders in a chemical plant, triggering circuit breakers within 20ms during short circuits using precise CT/VT signals.

Comparisons with Competing Products

Parameter GE UR8AH Siemens 7SJ61 CT/VT Module ABB REL650 CT/VT Input
CT Accuracy Class 0.5 Class 0.2 Class 0.1
VT Accuracy Class 1 Class 0.5 Class 0.2
Burden per Channel 5VA 10VA 3VA
Legacy Compatibility UR-9A/UR-9C/UR-9D Limited ABB REL650 series only
Configurable Signals 24 16 32
Operating Temp -40°C to +85°C -25°C to +70°C -40°C to +85°C
Cost-Effectiveness High (mid-precision, legacy support) Medium (premium accuracy, higher burden) Low (ultra-precision, limited compatibility)

Selection Suggestions and Precautions

Selection Suggestions

  • Choose GE UR8AH for retrofits of UR-9A/UR-9C/UR-9D systems needing CT/VT signal scaling and legacy compatibility.
  • Prefer it for medium-voltage feeders, transformers, and generators requiring Class 0.5/Class 1 accuracy and flexible configuration.

Precautions

  • Ensure secondary windings of CTs/VTs are grounded per local codes to maximize safety with GE UR8AH.
  • Match CT/VT ratios to system specs and configure via EnerVista UR software for optimal accuracy.
  • Use shielded cables for CT/VT wiring and separate analog/digital paths to minimize noise interference.
  • Verify compatibility with UR CPU modules and firmware version (3.5x or earlier) before installation.

74101-109-51 AB DCS
1336-SN-SP3A AB PLC/PC
80026-044-03 AB PLC
80190-240-02-R AB PLC
1756-ENBT AB PLC
80190-100-01-R AB PLC
40888-490-01-B1FX AB PLC
40382-074-53 AB PLC
CAT-1336S-B010-AA- AB PLC
1336F-BRF100-AA-EN AB PCS
1336T-B075-AA-GT2EN AB PLC

Reviews