Description
The ALSTOM MCTI40N1AB0751G is a high-precision, high-current current transducer designed for accurate measurement and isolation of AC currents in demanding industrial and power applications. It is part of Alstom’s (now likely under the Areva, GE Grid Solutions, or Hitachi Energy umbrella) measurement and protection portfolio, providing a critical input for control systems, energy metering, and protective relays by converting a primary AC current into a standardized, isolated secondary signal.
Product Description
The ALSTOM MCTI40N1AB0751G is a closed-loop (compensated) current transducer based on Hall-effect technology. Its primary function is to accurately and safely measure the magnitude of an AC current flowing through its primary conductor (a busbar or cable) and provide a proportional, galvanically isolated current or voltage output signal. This isolation is a key safety feature, protecting sensitive control electronics from the high-voltage primary circuit. Integrating the ALSTOM MCTI40N1AB0751G into a system ensures reliable and precise current data for functions like motor load monitoring, power factor correction, and fault detection. For system designers and maintenance engineers, this transducer offers a robust and maintenance-free alternative to traditional iron-core current transformers. The high accuracy and fast response time of the ALSTOM MCTI40N1AB0751G make it suitable for both steady-state monitoring and dynamic control applications. The performance and reliability of this transducer are critical for the safety and efficiency of the electrical system it monitors.
Product Parameters
-
Manufacturer: Alstom (legacy, product line now likely under GE Grid Solutions or Hitachi Energy).
-
Product Family: MCT series (Modular Current Transducer) or similar.
-
Model: MCTI40N1AB0751G.
-
Technology: Closed-loop Hall-effect transducer.
-
Primary Current (Ipn): Likely 40A (as indicated by “I40” in the model). The exact nominal primary current rating must be confirmed.
-
Output Signal: Typically a proportional DC current (e.g., 0-20 mA, 4-20 mA) or DC voltage (e.g., 0-10 V) signal.
-
Supply Voltage: Requires a dual DC supply voltage for operation (e.g., ±12Vdc, ±15Vdc, or ±24Vdc).
-
Accuracy: High accuracy class, often 0.5% or better of the measured value.
-
Response Time: Very fast response time (typically < 1 µs for step change), suitable for tracking rapid current changes.
-
Isolation: Provides high galvanic isolation between the primary circuit (high voltage/power) and the secondary measurement circuit (low voltage/control).
-
Mounting: Designed for DIN-rail mounting or panel mounting.
Advantages and Features
-
High Accuracy and Linearity: Provides excellent measurement precision over a wide range of currents, from small fractions of the nominal value up to and beyond the nominal rating, with minimal phase error.
-
Wide Frequency Bandwidth: Capable of measuring currents from DC up to high frequencies (often several kHz), making it suitable for measuring distorted currents (harmonics) and for fast control loops.
-
Galvanic Isolation: A key safety feature that completely separates the measurement circuit from the power circuit, protecting equipment and personnel.
-
Compact and Lightweight: Unlike traditional wound current transformers, the ALSTOM MCTI40N1AB0751G is compact and does not suffer from saturation issues, offering a smaller footprint.
-
Low Power Consumption: The measured primary circuit supplies no power to the transducer; it only requires a low-power auxiliary supply, making it efficient.
Application Cases in Industry
-
Variable Frequency Drives (VFDs): Used for precise motor phase current feedback within the drive’s control loop for torque and flux regulation.
-
Active Front End / AFE Units: Measures input current for harmonic mitigation and power factor correction systems.
-
UPS (Uninterruptible Power Supplies): Monitors battery charge/discharge current and output current for control and protection.
-
Renewable Energy Inverters: Measures AC output current of solar or wind inverters for grid synchronization and protection.
-
Industrial Power Monitoring: Used in switchgear and distribution panels for energy management, load profiling, and protective relay input.
Comparison with Competing Products
Competing current transducers come from manufacturers like LEM (IT, LT series), Danisense, and Texas Instruments. The ALSTOM MCTI40N1AB0751G competes directly with high-performance Hall-effect transducers from these brands. Its primary historical advantage was its integration into Alstom’s larger systems (like drives or protection panels). Compared to traditional current transformers (CTs), it offers DC measurement capability, no risk of saturation, and a wider frequency response. Compared to shunt resistors, it provides inherent isolation and can handle much higher primary currents.
Selection Suggestions and Precautions
-
Verify Electrical Specifications: Confirm the primary current rating (Ipn), output signal type/range, and required auxiliary supply voltage match your application’s requirements exactly.
-
Proper Primary Conductor Installation: The primary conductor (busbar or cable) must pass through the transducer’s aperture correctly. Ensure the conductor is centered and that the transducer is mounted away from strong external magnetic fields that could affect accuracy.
-
Auxiliary Power Supply Quality: Use a stable, well-regulated DC power supply with low noise/ripple. Poor supply quality will directly impact the transducer’s output accuracy and stability.
-
Output Signal Wiring: Use twisted-pair shielded cable for the output signal. Connect the shield to ground at one end only (typically the system/controller end) to prevent ground loops.
-
Source from Specialized Suppliers: Given that this is a legacy Alstom component, procure the ALSTOM MCTI40N1AB0751G from reputable industrial electronics suppliers specializing in measurement transducers or legacy Alstom parts. Ensure they can provide the original datasheet for verification.