Description

Product Parameters
| Parameter | Specification |
|---|---|
| Model | REG216 |
| Series | REG216 |
| Function | Numerical generator protection relay |
| Protection Functions | Differential, stator/rotor earth fault, over/under-voltage, over/under-frequency, loss of excitation, reverse power |
| Measurement Inputs | Current and voltage transformer inputs |
| Binary I/O | Configurable binary inputs and outputs for tripping and signalling |
| Communication | Serial / substation communication interfaces (per configuration) |
| Disturbance Recording | Integrated disturbance recorder |
| Mounting | Protection panel / rack installation |
| Operating Temperature | Power plant protection panel range |
| Diagnostics | Comprehensive self-diagnostics and event recording |
| Configuration | ABB protection relay engineering tools |
Advantages and Features
-
Comprehensive generator protection: The REG216 integrates a full suite of generator protection functions in a single relay, reducing panel space and wiring complexity.
-
Numerical measurement accuracy: Digital signal processing in the REG216 provides stable, accurate protection decisions with low drift.
-
Disturbance recording: Integrated recording in the REG216 supports post-event analysis and root-cause investigation.
-
Communication integration: The REG216 supports substation communication for SCADA and remote monitoring.
-
Comprehensive self-diagnostics: Continuous self-monitoring of the REG216 improves availability and supports maintenance planning.
-
Proven ABB protection platform: The REG216 builds on ABB’s long experience in generator and power system protection.
Application Cases in Application Fields
-
Power station generators: Main and auxiliary generator protection using the REG216 for internal fault and abnormal condition detection.
-
Combined heat and power plants: Protection of industrial and utility CHP generators with the REG216.
-
Industrial captive generation: Protection of generators in refinery, chemical, and manufacturing facilities.
-
Hydropower plants: Generator protection in hydroelectric stations using the REG216.
-
District energy systems: Protection of generators in district heating and cooling plants with the REG216.
Comparison with Competing Products
| Feature | ABB REG216 | Typical Competitor A | Typical Competitor B |
|---|---|---|---|
| Generator protection suite | Comprehensive | Comprehensive | Basic |
| Disturbance recording | Integrated | Optional | Integrated |
| Communication integration | Yes | Yes | Optional |
| Self-diagnostics | Comprehensive | Basic | Comprehensive |
| Configuration tool | ABB protection tools | Vendor-specific | Vendor-specific |
| Platform maturity | Proven REG216 series | Newer platform | Established platform |
The REG216 distinguishes itself through a comprehensive generator protection suite and integrated disturbance recording in a proven protection platform.
Selection Suggestions and Precautions
-
Confirm protection requirements: Verify that the protection function set of the REG216 covers all generator and system protection requirements identified in your protection study.
-
Verify CT/VT compatibility: Confirm that current and voltage transformer ratios and burden match the REG216 measurement input specifications.
-
Communication protocol: Confirm that the REG216 communication interface supports the protocol used by your substation automation or SCADA system.
-
Configuration backup: Save the relay configuration and settings file of the REG216 after commissioning so it can be restored after service or replacement.
-
Testing and commissioning: Perform secondary injection testing of all REG216 protection functions before energization and record results for compliance documentation.
-
Firmware compatibility: Confirm firmware and engineering tool versions are compatible with the REG216 revision in your system.
-
Spare parts: Given the critical role of the REG216 in generator protection, consider stocking a spare relay or ensuring rapid access to ABB service support.
-
Documentation: Retain protection settings, test records, and disturbance files for the REG216 for compliance and maintenance purposes.