Description
Product Parameters
- Brand: Vibro-Meter (Meggitt)
- Model: MPC4(200-510-071-113)+ IOC4T(200-510-111-034)
- Channels: 4 dynamic input channels + 2 tachometer speed channels
- Supported sensors: Eddy current probe, IEPE accelerometer, velocity sensor
- Measurable quantities: Shaft relative vibration, absolute vibration, thrust position, eccentricity, casing expansion, dynamic pressure
- Processing: Digital filtering, integration/differentiation, RMS/peak/peak-to-peak, order tracking
- Alarm: Alert / Danger two-stage threshold, delay, hysteresis, speed-adaptive trip setpoints
- Configuration software: VM600 MPSx
- Rack: VM600 ABE04 series rack
- Operating temperature: 0~60°C
- Status: Mk1 generation, discontinued, only refurbished/surplus spares; successor is MPC4Mk2 + IOC4Mk2Vibro-Mete…
Advantages and Features
One card covers most turbine protection measurements, flexible channel configuration. It supports order tracking for variable-speed rotating machines, adaptive threshold for critical speed crossing. Built-in sensor cable fault detection (open/short circuit). BNC buffered raw signal output for on-site debugging. IOC4T provides isolated analog output and relay alarm for DCS/SIS interlock. It is widely recognized for turbine protection in power and oil & gas.
Application Cases and Application Fields
Used for steam turbine, gas turbine, centrifugal compressor, large pump in power plant, refinery, petrochemical, offshore platform. Typical monitoring: shaft vibration, thrust bearing displacement, rotor speed, casing expansion. When the MPC4/IOC4T set fails, the machine protection loop is lost; replacing the card set restores machinery protection and alarm trip functions.
Comparisons with Competing Products
MPC4+IOC4T is Mk1 pair; MPC4Mk2+IOC4Mk2 is Mk2 and cannot be directly swapped. MPC4 is processing card, IOC4T is matched I/O daughter card, they must be used together. Different part number suffixes of MPC4 correspond to standard / SIL safety versions. It is different from AMC10 temperature monitoring card of VM600.
Selection Suggestions and Precautions
Confirm the full part numbers of both MPC4 and IOC4T, cannot mix different versions. For refurbished units, test channel sampling, tacho input, relay and analog output before installation. Before replacement, take machine protection bypass according to interlock management procedure. After installation, connect MPSx software, load original configuration, verify measurement values, alarm and trip logic, remove bypass after confirming normal, confirm that the VIBRO-METER VM600 MPC4 set works reliably.