Description

Specifications
- Part Number: PR6423/000-031-CN + CON021
- Probe type: Eddy current probe
- Measuring range: 0 ~ 2 mm
- Cable length: 3 m
- Output of CON021: -24 VDC power supply input, voltage output proportional to gap
- Sensitivity: 8 V/mm
- Material: Stainless steel probe, corrosion resistant
- Operating temperature of probe: -40°C ~ +170°C
- Operating temperature of CON021: -40°C ~ +85°C
- Protection: IP67 for probe head
- Matching monitor: MMS3210, MMS3000 series rack monitors
Advantages and Features
EPRO PR6423000-031-CN+CON021 features high stability and high linearity, suitable for long-term online monitoring of rotating equipment. It is not affected by lubricating oil, water vapor and dust between probe and shaft. Built-in temperature compensation reduces measurement drift under large temperature variation. The whole set includes probe, extension cable and CON021 converter, which is convenient for on-site installation and calibration. It meets API 670 standard for machinery protection.
Application & Case
It is applied to steam turbine, gas turbine, centrifugal compressor and large blower thrust and vibration monitoring. In a power plant TSI overhaul project, PR6423000-031-CN+CON021 replaced the old probe assembly. After gap calibration, shaft vibration and thrust displacement measurement returned stable, and alarm functions worked normally.
Comparison
Compared with PR6424 series probes, PR6423 is the standard 8V/mm specification. Different probe diameters, cable lengths and sensitivity versions cannot be directly replaced. CON021 must be matched with PR6423 series probes; it cannot be mixed with PR9268 seismic vibration sensors. It is incompatible with Bently 3300 series probe systems.
Selection Notes
Confirm the full set: PR6423/000-031-CN + CON021. Confirm cable length, sensitivity and matching MMS monitor model. This is a legacy EPRO spare.
Precautions
Avoid collision of the probe thread and front sensing surface during installation. Adjust the gap to the linear range before power-on. Do not damage the coaxial cable. After installation, calibrate the gap and voltage, check linearity, and verify measurement value and alarm interlock before putting into service.



Reviews