Description

Specifications
- Part Number: 3500/22M, Order code: 138607-02
- Series: Bently Nevada 3500 TSI system
- Power consumption: 10.5 W
- Communication: 10/100 Mbps Ethernet RJ45, USB port for local configuration
- Indicators: LEDs for OK, TX/RX, TMR status and rack trip
- Operating temperature: -30°C ~ +65°C
- Storage temperature: -40°C ~ +85°C
- Humidity: 0–95%, non-condensing
- Installation: Full-height slot inside the 3500 rack
- TMR option: This part number supports TMR triple redundant rack configuration
Advantages and Features
BENTLY 3500/22M 138607-02 integrates the old rack interface function and high-speed transient data acquisition function. It supports fault waveform capture for post-event analysis of turbine, compressor and fan faults such as rotor rub and unbalance. It has built-in rack diagnostic function. The front reset button can be used for alarm reset, and a lock function prevents unauthorized modification of configuration. It is widely used for steam turbine and gas turbine supervisory instrumentation cabinets in power plants.
Application & Case
It is used in large rotating equipment monitoring cabinets of thermal power plants, combined-cycle power stations and petrochemical plants. In a turbine TSI maintenance project, 3500/22M 138607-02 replaced the faulty TDI module. After commissioning, vibration, shaft displacement and speed data, alarm messages and transient waveform uploading to System 1 returned normal.
Comparison
Compared with 146031-01 (another 3500/22M ordering variant), 138607-02 is a different revision. They are hardware version variants of the same 3500/22M TDI series and cannot be replaced directly without firmware verification. It is only a communication gateway and does not process probe signals. It is not interchangeable with monitor cards like 3500/40M. Generic Ethernet modules cannot recognize the proprietary Bently TDI protocol.
Selection Notes
Confirm the full part number 138607-02 and confirm whether the rack is TMR configuration. It must be placed in Slot 1 of the 3500 rack. It is not compatible with the old 3300 series monitoring racks.
Precautions
Power off the rack and take ESD protection before replacement. Check Ethernet cable and IP address after installation. Refresh rack information in System 1, verify channel readings, alarm upload and transient waveform capture. Confirm stable communication before putting into service.