Description
Parameters
| Parameter | Specification |
|---|---|
| Input Channels | 16, optically isolated |
| Output Channels | 16, solid-state (MOSFET) |
| Input Voltage Range | 0–60VDC (threshold: 12V min for ON) |
| Output Voltage Range | 24–48VDC (sourcing or sinking, configurable per channel) |
| Output Current per Channel | 2A continuous; 5A surge (1s) |
| Total Output Current | 16A (max) |
| Input Debounce | Programmable: 0.1ms–100ms |
| Input Wetting Current | 5–15mA (programmable per channel) |
| Diagnostics | Open-wire detection, short-circuit detection, over-temperature, input state readback |
| Protection | Short-circuit protection (3.5A limit), thermal shutdown (95°C), reverse polarity protection |
| Isolation | 2500Vrms (I/O to backplane); 500VDC (channel-to-channel) |
| Update Rate | 1ms (deterministic) |
| Power Supply | 24VDC (aux, logic and wetting), 400mA + output load |
| Operating Temp | -40°C to +70°C |
| Mounting | Eurocard (6U, 160mm) |
| Certifications | UL, CSA, ATEX Zone 2, SIL 2 capable |
Advantages & Features
-
Combined I/O Density – The ABB 3BHE004573R0145 UFC760BE145 provides 16 inputs and 16 outputs in a single slot, reducing rack space and simplifying wiring.
-
Configurable Sourcing/Sinking – Each output channel can be independently configured for high-side (sourcing) or low-side (sinking) switching.
-
Comprehensive Diagnostics – Continuous open-load, short-circuit, and over-temperature detection with fault reporting to the controller.
-
Programmable Debounce – Per-channel debounce settings for reliable reading of noisy field contacts.
-
High Surge Capability – 5A surge for 1s, suitable for solenoid and relay loads.
-
SIL 2 Capable – Suitable for safety-critical applications with appropriate proof-testing.
Application Cases
-
Turbine Valve Control – Monitors 16 valve limit switches and controls 16 solenoid valves (24VDC) in steam or gas turbine auxiliary systems.
-
Generator Auxiliary Control – Reads breaker status contacts and controls cooler fans and heaters.
-
Motor Control Centers – Monitors starter auxiliary contacts and controls contactor coils.
-
ESD System Interface – Monitors field pressure/temperature switches and drives shutdown relays.
Competitor Comparison
| Feature | ABB 3BHE004573R0145 | Siemens 6ES7422-1BL00 + DI | GE DS4815CHGA | Rockwell 1756-OB16E + IB16 |
|---|---|---|---|---|
| Combined I/O in 1 slot | Yes (16+16) | No (separate) | Yes (16+16) | No (separate) |
| Voltage Range | 24–48VDC | 24–240VAC/VDC | 24–250VAC/VDC | 24–240VAC/VDC |
| Configurable Sourcing/Sinking | Yes (per channel) | No | Yes (per channel) | No |
| Input Wetting Current | Yes (programmable) | No | Yes | No |
| Output Surge Current | 5A (1s) | 2A | 5A (1s) | 2A |
| SIL Rating | SIL 2 | SIL 1 | SIL 2 | SIL 1 |
| Integration | ABB System 800xA | Siemens TIA | GE Mark VIe | Rockwell Logix |
The ABB 3BHE004573R0145 UFC760BE145 offers combined 16+16 I/O density and per-channel sourcing/sinking configurability, making it the most flexible solution for 24–48VDC control applications.
Selection Suggestions
-
Choose for ABB System 800xA applications requiring 16 inputs and 16 outputs in one slot for 24–48VDC field devices.
-
If higher voltage (125VDC/240VAC) is required, use the UFC760BE142 variant.
-
For SIL 2 applications, use with external voting logic and periodic proof-testing (every 24 months).
-
Pair with matching ABB TU810 or TU830 termination unit.
Precautions
-
Output Grouping – All outputs share a common return. Ensure all outputs are powered from the same voltage source.
-
Output Current Limit – Total output current limited to 16A. Do not exceed this limit.
-
Wetting Current – For dry contacts, enable wetting current (5–15mA) for reliable switching.
-
Surge Current – Repetitive surge cycling may reduce module life; use external relays for frequent high-inrush loads.
-
Power Supply – The module draws 400mA from 24V aux plus output load. Ensure adequate capacity.
-
Firmware – Requires ABB firmware version compatible with System 800xA 6.0 or higher.
-
ESD Handling – Use ESD-safe practices when handling the module.