Description
Parameters
| Parameter | Specification |
|---|---|
| Input Voltage | 85–264VAC (47–63Hz) or 100–300VDC (automatic sensing) |
| Output 1 | 24VDC, 10A continuous (regulated) |
| Output 2 | 5VDC, 5A continuous (regulated) |
| Output 3 | 24VDC aux (unregulated, for field loops), 2A |
| Total Output Power | 300W max (combined) |
| Efficiency | >88% at full load |
| Isolation | 3000VAC input-to-output; 1500VAC output-to-output |
| Hold-up Time | >20ms at full load (115VAC input) |
| Ripple & Noise | <50mVpp (24V), <20mVpp (5V) |
| Protection | Overvoltage (crowbar), overcurrent (hiccup), over-temperature, short-circuit |
| Alarm Outputs | 2x Form-C relays (rated 2A@30VDC) for DC OK and alarm status |
| Display | LCD: input voltage, output voltage/current, temperature, load % |
| Redundancy | Active ORing diodes for parallel operation (hot-swap) |
| Operating Temp | -40°C to +70°C (derate 2.5%/°C above 60°C) |
| Mounting | 6U VME Eurocard, 160mm depth |
| Certifications | UL 508, CSA C22.2, ATEX Zone 2, CE, DNV GL |
Advantages & Features
-
Universal Input – The GE DS3820EPSA accepts both AC (85–264V) and DC (100–300V) without configuration changes, simplifying global installation and eliminating input selection errors.
-
Built-in Redundancy – Two GE DS3820EPSA modules can be paralleled using built-in ORing diodes. If one fails, the other automatically carries the full load with zero voltage drop (<0.3V differential).
-
Comprehensive Diagnostics – The front-panel LCD displays real-time parameters, while alarm relays provide remote fault notification. The GE DS3820EPSA also reports status to the Mark VIe controller via the backplane for system-level monitoring.
-
High Efficiency – >88% efficiency reduces heat generation, allowing operation up to 70°C with minimal derating, critical for turbine cabinet installations with limited cooling.
-
Hot-Swappable – The GE DS3820EPSA can be replaced without powering down the rack, supporting online maintenance in critical power generation applications.
-
Hold-up Time – 20ms hold-up ensures the GE DS3820EPSA rides through brief power dips without causing I/O module resets.
Application Cases
-
Gas Turbine Control Cabinet – A single GE DS3820EPSA powers the entire Mark VIe rack (CPU, I/O modules, communication cards) in a 7FA gas turbine installation, with a redundant second module providing N+1 backup.
-
Steam Turbine Retrofit – Replaces legacy Mark IV power supplies (multiple 125VDC bricks) with a single GE DS3820EPSA, reducing cabinet size and improving reliability.
-
Offshore Platform – Two GE DS3820EPSA modules operate in redundant parallel with separate input feeds (UPS and emergency diesel), ensuring continuous power during transfer switching.
-
Combined-Cycle Plant – Powers Mark VIe I/O racks distributed across HRSG and turbine areas, with alarm relays connected to DCS for remote status monitoring.
Competitor Comparison
| Feature | GE DS3820EPSA | Siemens 6ES7407-0KA02 | ABB SD822 | Rockwell 1756-PA75 |
|---|---|---|---|---|
| Input Range | 85–264VAC / 100–300VDC | 85–264VAC only | 120–230VAC only | 85–264VAC / 125VDC |
| Total Power | 300W | 240W | 200W | 150W |
| 24V Output | 10A | 10A | 8A | 6A |
| 5V Output | 5A | 4A | 3A | 4A |
| LCD Display | Yes | No | No | No |
| Alarm Relays | Yes (2x) | Yes (1x) | Yes (1x) | Yes (1x) |
| Efficiency | >88% | >85% | >85% | >82% |
| Temp Range | -40 to +70°C | 0 to +60°C | -25 to +70°C | 0 to +60°C |
| Hot-Swap | Yes | Yes | No | Yes |
| Redundancy | ORing diodes included | External required | External required | External required |
The GE DS3820EPSA offers wider input range, more outputs (24V + 5V + aux 24V), higher efficiency, and built-in LCD compared to competitors. ABB lacks hot-swap capability; Rockwell’s lower power output limits rack expansion.
Selection Suggestions
-
Select the GE DS3820EPSA as the default power supply for any Mark VIe rack, regardless of input source (AC or DC). Its universal input eliminates ordering errors.
-
For N+1 redundancy, install two GE DS3820EPSA modules in the same rack. Both must be powered from separate input sources for true fault tolerance.
-
Calculate total rack power: sum 24V and 5V loads of all modules. The GE DS3820EPSA provides 10A at 24V and 5A at 5V — sufficient for typical 10-slot racks with 8 I/O modules.
-
If rack expansion exceeds 300W, use the GE DS3820EPSA-HD variant (not this model) or distribute loads across multiple racks.
-
Connect alarm relays (normally energized) to your DCS for remote fault indication. Relay contacts are rated 2A@30VDC.
-
For marine/offshore installations, verify the GE DS3820EPSA has DNV GL certification (available as option).
Precautions
-
Input Wiring – Use appropriate wire gauge for input current (max 4A at 115VAC, 2A at 230VAC). AC input must use 3-wire (L,N,G) with ground connected to cabinet ground bus.
-
Output Loading – Do not exceed 10A on 24V output. The GE DS3820EPSA limits current at 11.5A (hiccup mode); excessive loads will cause cyclic power cycling.
-
Parallel Operation – When using redundant GE DS3820EPSA modules, ensure both are powered on and stable for at least 3 seconds before loading. ORing diodes handle sharing but do not provide active current balancing — one unit may carry slightly more load.
-
Thermal Derating – Above 60°C ambient, derate output power by 2.5%/°C. At 70°C, maximum output is reduced to 225W. Ensure cabinet ventilation meets the module’s airflow requirement (50 CFM recommended).
-
Mounting Orientation – The GE DS3820EPSA must be mounted vertically (as in VME rack) for proper convection cooling. Horizontal mounting is not permitted.
-
Battery Backup – The GE DS3820EPSA is not a battery charger. If backup batteries are required, use a separate charger module and connect batteries through external ORing diodes.
-
LCD Cleaning – Use only dry cloth; solvents will damage the display coating.
-
Calibration – The GE DS3820EPSA is factory-calibrated and does not require field calibration. LCD display accuracy is ±2% of reading — verify with external meter for critical measurements.
-
Replacement – When replacing a failed GE DS3820EPSA in a redundant pair, insert the new module, wait 5 seconds for stabilization, then remove the old module. Do not remove the active module first.