GE DS3810MTRA

¥999.00

The DS3810MTRA is a specialized memory and time-stamp recorder board for the GE Mark IV turbine control system. It combines non-volatile memory storage with high-accuracy time-stamping capabilities for recording turbine events, alarms, trips, and operational data. This board is designed to provide a detailed, time-correlated history of turbine operations, enabling root-cause analysis, maintenance planning, and performance trending. It works alongside boards such as the DS3800NVIA1G1CDS3800NVIA1G1DDS3800NVMBDS3810MMAB, and DS3800SCG.

Category:

Description

Key Parameters

  • Memory Type: Battery-backed SRAM with integrated real-time clock (RTC)

  • Memory Capacity: 2MB or 4MB (depending on configuration)

  • Time-Stamp Resolution: 1ms (high-accuracy event logging)

  • Real-Time Clock: Integrated RTC with battery backup (maintains time during power loss)

  • Time-Stamp Accuracy: ±2 seconds per day (temperature-compensated)

  • Data Retention: >10 years with battery (battery-backed memory)

  • Battery: Field-replaceable lithium 3.6V (life ~5 years) – separate battery for RTC backup

  • Battery Monitoring: On-board voltage monitoring for both memory and RTC batteries, low-battery alarm

  • Diagnostics: LED status (power, battery, RTC, activity), self-test on power-upRTC health indication

  • Event Logging: Configurable event buffers for trip events, alarms, operator actions, and analog value snapshots

  • Isolation: 1500V RMS memory-to-backplane

  • Temp Range: –30°C to +70°C

  • Power Supply: +5V (logic) from backplane; battery backup for memory and RTC

  • Physical: 6U VME single-slot board

  • Key Features: Battery-backed memory + RTC, 1ms time-stamp resolution, event logging, dual battery monitoring, self-test


Advantages

  • High-accuracy time-stamping – the DS3810MTRA provides 1ms time-stamp resolution, enabling precise correlation of turbine events, alarms, and trips for root-cause analysis.

  • Integrated RTC with battery backup – maintains accurate time even during extended power outages, ensuring all events are correctly time-stamped.

  • Comprehensive event logging – stores trip events, alarms, operator actions, and analog value snapshots in a time-correlated format.

  • Dual battery monitoring – the General Electric DS3810MTRA monitors both the memory and RTC batteries, providing early warning of depletion.

  • Data persistence – preserves event logs and configuration data through power cycles.

  • Self-test on power-up – verifies memory integrity, RTC functionality, and battery health at system startup.

  • Drop-in compatible – works with all Mark IV backplanes and processor configurations.


Applications

  • Turbine event recording – the DS3810MTRA records trip events, alarm activations, and operator actions with precise time-stamps for root-cause analysis.

  • Fault diagnosis – time-correlated event logs help identify sequence-of-events leading to turbine trips, enabling faster troubleshooting.

  • Performance trending – stores operational data with time-stamps for performance analysis and predictive maintenance.

  • Sequence-of-events recording – the General Electric DS3810MTRA provides high-resolution time-stamping for critical sequence-of-events (SOE) applications.

  • Compliance and reporting – maintains detailed, time-stamped logs for regulatory compliance and operational reporting.

  • Retrofits – replaces older event recorders with an integrated VME solution.


vs Competitors & Previous Variants

Feature DS3810MTRA DS3810MMAB1A1A (Memory only) DS3800NVMB (Memory only) External SOE Recorder
Memory capacity 2–4MB 2–4MB 512KB Varies
Time-stamp resolution 1ms None None 1ms
Integrated RTC Yes No No Yes (external)
RTC battery backup Yes N/A N/A Yes
Event logging Yes (configurable) No No Yes
Dual battery monitoring Yes Yes (memory only) Limited Varies
Isolation 1500V 2500V 1500V Varies
Board count 1 1 1 1+ (external)

Selection Tips

  • Time-stamped event logging – choose the DS3810MTRA when you require high-accuracy time-stamping (1ms) for sequence-of-events recording, fault diagnosis, or compliance logging.

  • Combined memory + RTC – the General Electric DS3810MTRA integrates both non-volatile memory and a battery-backed real-time clock in a single board, saving rack space.

  • Event correlation – for root-cause analysis of turbine trips, the time-correlated event logs from the DS3810MTRA are essential.

  • Battery management – monitor both the memory and RTC batteries on the DS3810MTRA; replace both batteries when the low-battery alarm indicates.

  • Spare strategy – keep one DS3810MTRA per 5–8 installed units, especially in systems where event logging is critical.

  • Pre-installation verification – verify battery voltages and RTC accuracy before installation.

  • Configuration – configure the event logging parameters (buffer size, events to log) to match your application requirements.


Critical Precautions

  • Battery handling – replace the batteries on the DS3810MTRA only with the specified lithium 3.6V type. Use correct polarity for both the memory and RTC batteries.

  • Battery replacement procedure – when replacing batteries on the General Electric DS3810MTRA, ensure the board is powered (or data/event logs are backed up) to prevent data loss.

  • Data backup – before any maintenance, export all event logs and configuration data using the Mark IV system tools.

  • RTC accuracy – verify the RTC accuracy of the DS3810MTRA periodically; temperature-compensated accuracy is ±2 seconds/day.

  • Time synchronization – if the Mark IV system has a master time source, ensure the DS3810MTRA RTC is synchronized to maintain consistent time-stamps.

  • Event log management – configure the DS3810MTRA event buffer size appropriately; if the buffer fills, older events may be overwritten.

  • ESD handling – always use a grounded wrist strap when handling the DS3810MTRA; CMOS memory and RTC components are ESD-sensitive.

  • Battery disposal – dispose of the DS3810MTRA lithium batteries according to local environmental regulations.

  • Hot-swap – never insert or remove the DS3810MTRA while the rack is powered; this can cause data or event log corruption.

  • Low-battery alarm – if the low-battery alarm is active for either the memory or RTC battery, replace the affected battery as soon as possible.

  • Storage – store spare DS3810MTRA boards in anti-static bags in a dry, temperature-controlled environment. Batteries should be stored separately if the board will be in storage for more than 6 months.

  • Battery shelf life – check the battery date codes on the DS3810MTRA before installation; batteries have a limited shelf life (typically 5 years from manufacture).

PANASONIC BR-AGCF2W 6V
AB 889D-M4AC-5
PANASONIC BR-2/3AGCT4A 6V

Reviews

There are no reviews yet.

Be the first to review “GE DS3810MTRA”

Your email address will not be published. Required fields are marked *

Post comment