Description
Key Parameters
-
Power Outputs: Multiple regulated DC outputs (+5V, ±15V, +24V, and configurable auxiliary outputs)
-
Excitation Outputs: Adjustable excitation for transducers (e.g., 3V, 5V, 10V DC, or 4–20mA loop power)
-
Input Voltage: 120/240V AC or 125/250V DC (depending on system configuration)
-
Output Accuracy: ±0.05% regulation (improved)
-
Ripple/Noise: <3 mV peak-to-peak (improved)
-
Current Capacity: Higher than standard boards (per output, consult board marking)
-
Isolation: 2500V RMS input-to-output
-
Diagnostics: LED status indicators for each output, over-voltage/over-current protection, thermal shutdown, output voltage monitoring
-
Temp Range: –30°C to +70°C
-
Physical: 6U VME single-slot board
-
Key Features: Multiple regulated outputs, adjustable excitation, low noise (<3 mV), higher current capacity, short-circuit protection, thermal shutdown, output voltage monitoring
Advantages
-
Superior regulation – ±0.05% output regulation ensures stable excitation even under varying load conditions, critical for high-precision sensors.
-
Ultra-low noise – <3 mV ripple provides exceptionally clean power for sensitive analog measurements, improving signal-to-noise ratio.
-
Higher current capacity – the DS3800XPEN can supply more current than standard boards, supporting multiple sensors or long cable runs.
-
Adjustable excitation – allows matching excitation levels to specific sensor requirements.
-
Output voltage monitoring – the General Electric DS3800XPEN includes monitoring circuits that alert the system to output voltage deviations.
-
Comprehensive protection – over-voltage, over-current, and thermal protection safeguard the board and connected field devices.
-
Diagnostic visibility – LED indicators and monitoring outputs simplify troubleshooting of power supply issues.
-
Drop-in compatible – works with all Mark IV backplanes and processor configurations.
Applications
-
Speed pickup excitation – provides stable power to magnetic pickups for turbine speed measurement and overspeed protection.
-
Proximity probe excitation – supplies low-noise power to eddy-current probes for shaft vibration and position monitoring.
-
LVDT excitation – powers LVDTs for precise valve position feedback (IGVs, fuel valves, steam valves).
-
Pressure transmitter power – provides loop power for 2-wire 4–20mA pressure transmitters.
-
RTD excitation – supplies constant current for RTD temperature measurement.
-
Long cable runs – the higher current capacity of the DS3800XPEN compensates for voltage drop in long sensor cables.
-
Retrofits – the DS3800XPEN replaces aging power supply modules in legacy Mark IV systems with improved performance.
vs Competitors & Previous Variants
| Feature | DS3800XPEN | DS3800XPEM1C1E | Generic VME Power/Exciter Board |
|---|---|---|---|
| Output regulation | ±0.05% | ±0.1% | ±0.1–0.5% |
| Ripple/noise | <3 mV | <5 mV | 10–50 mV |
| Current capacity | Higher | Standard | Limited |
| Output voltage monitoring | Yes | No | Rarely |
| Adjustable excitation | Yes | Yes | Rarely |
| Isolation | 2500V | 2500V | 500–1500V |
| Over-current protection | Yes (per output) | Yes (per output) | Sometimes |
| Thermal shutdown | Yes | Yes | Rarely |
| Diagnostic LEDs | Yes | Yes | Limited |
| Temp range | –30°C to +70°C | –30°C to +70°C | 0°C to +60°C |
Selection Tips
-
High-precision sensors – choose the DS3800XPEN for applications requiring the lowest noise and tightest regulation (e.g., vibration monitoring, precision speed control).
-
Multiple sensors / long cables – the higher current capacity makes the General Electric DS3800XPEN suitable for powering multiple sensors or installations with long cable runs.
-
Sensor compatibility – verify that the excitation voltage and current requirements of your sensors match the DS3800XPEN outputs.
-
Output configuration – ensure that the jumpers or DIP switches on the DS3800XPEN are set correctly for your required output voltages.
-
Power loading – calculate the total current draw of all connected sensors and ensure it does not exceed the DS3800XPEN total power rating.
-
Spare strategy – keep one DS3800XPEN per 5–8 installed units, especially in critical measurement applications.
-
Calibration – periodically verify output voltages under load using a precision multimeter to ensure the ±0.05% accuracy.
Critical Precautions
-
Output voltage selection – verify that the DS3800XPEN output voltages are correctly configured before connecting sensors. Incorrect voltage can damage sensors.
-
Overloading – do not exceed the DS3800XPEN current rating for any output. Overloading can cause voltage drop, overheating, or shutdown.
-
Wiring polarity – ensure correct polarity when connecting sensors to the General Electric DS3800XPEN outputs; reversed polarity can damage sensitive transducers.
-
Shielded cabling – use shielded cables for sensor connections to minimize noise pickup. Ground the shield only at the DS3800XPEN end to prevent ground loops.
-
Ground loops – use single-point grounding for all sensors connected to the DS3800XPEN to avoid ground-loop noise that can affect measurements.
-
Output monitoring – if the DS3800XPEN includes monitoring outputs, connect them to the appropriate analog inputs for continuous voltage verification.
-
Thermal considerations – ensure adequate cabinet cooling; the DS3800XPEN can generate significant heat under load, especially at higher current outputs.
-
Hot-swap – never insert or remove the DS3800XPEN while the rack is powered; this can cause voltage spikes and damage connected sensors.
-
ESD handling – always use a grounded wrist strap when handling the DS3800XPEN; power components are ESD-sensitive.
-
Ripple check – if measurement noise issues arise, check the DS3800XPEN output ripple with an oscilloscope; excessive ripple may indicate failing capacitors.
-
Storage – store spare DS3800XPEN boards in anti-static bags in a dry, temperature-controlled environment.

A-B 1756-BA2
Schneider IC65N 3P D6A
A-B 1756-N2


Reviews