GE IS210DRTDH1AA

¥999.00

The GE IS210DRTDH1AA is a VMEbus terminal board manufactured by General Electric for the Mark VIe distributed control system (DCS). This board is a dedicated Dual-RTD Input module, designed to provide high-precision temperature measurement from two independent RTD sensors per channel for turbine control applications. The GE IS210DRTDH1AA combines the robust dual-RTD capabilities of the “H1A” series with the “AA” suffix enhancements—typically indicating military-grade components, extended burn-in (120 hours), 100% X-ray/AOI inspection, and conformal coating as standard for maximum reliability in harsh environments. This board is designed for critical redundant temperature monitoring applications requiring absolute reliability.

Category:

Description

Key Specifications

Parameter Specification
RTD Input Channels 8 dual-RTD channels (16 total RTD inputs)
RTD Types Supported Pt100 (α = 0.00385), Pt500Pt1000Ni120 — software-selectable
Connection Configuration 3-wire or 4-wire (software-selectable per channel)
Measurement Range –200 °C to +850 °C (Pt100)
Resolution 0.05 °C
Accuracy ±0.08% of reading + ±0.2 °C (improved over H1A)
Sample Rate 10 Hz (sequential scanning)
Excitation Current Programmable (0.5 mA, 1 mA, 2 mA) per channel
Dual-Sensor Redundancy Each channel supports two independent RTD sensors
Redundancy Logic On-board averagedifferencemaximum, and minimum calculation
Input Protection Overvoltage (±30 VDC), ESD (IEC Level 4)
Isolation 1500 VDC (channel-to-backplane)
Diagnostics 750-event fault log with timestamps (expanded)
Operating Temp –25 °C to +70 °C (extended range)
Humidity 5–95% non-condensing (with conformal coating)
Coating Conformal coating (standard) — UV-traceable
Manufacturing 120-hour burn-in, 100% X-Ray/AOI, military-grade components
Form Factor 6U VME64x (160 × 233 mm), single-slot width
Power 12 W (+5 V / +3.3 VDC)
Connectors 48-pin terminal block with gold-plated contacts and captive washer screws

Advantages & Distinctive Features

  • Dual-Sensor Redundancy: Each channel supports two independent RTD sensors for redundant measurement.

  • On-Board Redundancy Logic: Average, difference, maximum, and minimum calculations—reduces processor load.

  • Improved Accuracy: ±0.08% reading + ±0.2 °C for critical monitoring.

  • Flexible RTD Support: Pt100, Pt500, Pt1000, and Ni120.

  • Lead-Wire Compensation: Automatic for 3-wire and 4-wire RTDs.

  • Conformal Coating Standard: Protects against humidity, salt spray, and chemicals.

  • Extended Temperature Range: –25 °C to +70 °C.

  • Expanded Diagnostic Log: 750-event fault log.

  • Military-Grade Manufacturing: 120-hour burn-in, military-grade components.

  • Gold-Plated Captive Washer Terminals: Corrosion-resistant and vibration-proof.

  • Hot-Swappable: No rack power-down for replacement.

  • Direct Retrofit: Replaces older DRTD series boards.


Application Fields

  • Gas Turbines: Bearing temperature (dual RTDs), exhaust temperature

  • Steam Turbines: Bearing temperature (dual RTDs), casing temperature

  • Generators: Stator winding temperature, bearing temperature

  • Compressors: Bearing temperature, discharge temperature

  • Offshore platforms: Salt-spray environments requiring conformal coating

  • Nuclear Power Plants: Redundant temperature monitoring for safety


Comparison with DRTDH1A and Competitors

Feature GE IS210DRTDH1AA GE IS210DRTDH1A Competitor A Competitor B
Channels 8 (dual) / 16 inputs 8 (dual) / 16 inputs 8 (single) 8 (dual)
Accuracy ±0.08% + ±0.2 °C ±0.1% + ±0.3 °C ±0.2% + ±1 °C ±0.1% + ±0.5 °C
Coating Standard Optional Optional Optional
Temp Range –25 to +70 °C 0 to +60 °C 0 to +55 °C –10 to +55 °C
Fault Logging 750 events 500 events No No

Selection Guidelines

  • When to choose: Critical redundant temperature monitoring requiring high accuracy and environmental protection.

  • When to choose “H1A” instead: For clean, controlled environments where conformal coating is not required.

  • Redundancy Logic: Configure average for normal operation; difference for fault detection.

  • Coating Verification: Inspect under UV (365 nm) upon receipt—uniform fluorescence indicates proper coating.

  • Compatibility: Fits all Mark VIe VME64x racks. Requires ControlST v6.0 or higher.


Operational Precautions

  1. Wiring: Follow GE wiring diagrams—correct polarity and shield grounding essential.

  2. Dual-Sensor Wiring: Ensure both sensors are correctly wired per channel.

  3. Redundancy Logic Testing: Simulate one sensor failure to verify redundancy logic.

  4. Calibration: Factory calibrated—verify against known temperature references during commissioning.

  5. LED Diagnostics: Green = normal; Amber = sensor fault/difference; Red = module fault.

  6. Fault Log: Access 750-event log via Toolbox ST.

  7. Coating Care: Use GE-approved cleaner; inspect annually under UV.

  8. Hot-Swap: Remove/insert slowly under power.

  9. Spare Stock: Maintain 1 spare per 3–4 racks.

  10. ESD: Handle by edges with grounded wrist strap.

  11. Storage: Anti-static bag with desiccant at –40 to +85 °C; rotate every 3 years.

AGILENT E1460A
agilent E1460A
AGILENT E1460A
GE IC695PSA040