Description
Key Specifications
| Parameter | Specification |
|---|---|
| Output Channels | 16 discrete outputs (high-side or low-side configurable) |
| Output Type | Solid-state (MOSFET) with improved switching characteristics |
| Voltage Rating | 24 VDC nominal (18–32 VDC) |
| Current/Channel | 2.5 A continuous, 6 A inrush (150 ms) |
| Total Current | 16 A max (module total) |
| Protection | Short-circuit, overcurrent, over-temperature, inductive load clamp (built-in flyback), reverse polarity protection |
| Diagnostics | Per-channel load current monitoring with ±5% accuracy, output state feedback, wire-break detection |
| Fault Logging | 1000-event log with timestamps and waveform snapshots (expanded over H1B) |
| Isolation | 1500 VDC (output-to-backplane) |
| Operating Temp | –25 °C to +70 °C (extended over H1B) |
| Humidity | 5–100% condensing (with conformal coating) |
| Coating | Conformal coating (standard) — acrylic or silicone-based (verify with GE), UV-traceable |
| Manufacturing | 96-hour burn-in, 100% X-Ray/AOI inspection, premium component selection |
| Power | 10 W (+5 V / +3.3 VDC) + external 24 VDC field power |
| Connectors | Front-panel 32-pin terminal block with captive washer screws |
| Status Indicators | Individual channel LEDs, module health, communication status, diagnostic blink codes |
Advantages & Distinctive Features
-
16 High-Capacity Outputs: Controls up to 16 solenoids/actuators per module—reduces rack space and cost.
-
High Inrush Capability: 6 A for 150 ms handles demanding solenoid loads and long-cable capacitive inrush.
-
Improved Current Monitoring: ±5% accuracy enables precise detection of solenoid degradation (increased coil resistance) and predictive maintenance.
-
Wire-Break Detection: Identifies open circuits in field wiring—prevents unexpected valve failures.
-
Reverse Polarity Protection: Protects module from field power wiring errors—reduces installation risk.
-
Conformal Coating Standard: UV-traceable coating protects against humidity, salt spray, and chemical vapors—suitable for coastal, offshore, and industrial environments.
-
Extended Temperature Range: –25 °C to +70 °C operation—suitable for unheated cabinets and harsh environments.
-
1000-Event Fault Log with waveform snapshots—enables comprehensive post-event analysis.
-
Captive Washer Terminals: Prevents screw loosening due to vibration—essential for turbine control cabinets.
-
Hot-Swappable: Supports removal and replacement without powering down the rack.
-
Direct Retrofit: Replaces all VSVOH1A and VSVOH1B series boards.
Application Fields
-
Gas Turbines: Trip solenoids, fuel shut-off valves, purge/drain valves, start-up bleed valves, liquid fuel dump valves
-
Steam Turbines: Emergency stop valves (ESV), control valve trip solenoids, extraction valves, drain valves
-
Compressors: Anti-surge blow-off valves, suction/discharge isolation valves, vent valves
-
Generators: H2 supply shut-off valves, seal oil system valves, CO2 fire suppression valves
-
Combined Cycle: HRSG drain valves, feedwater isolation valves, blowdown valves
-
Offshore Platforms: Salt-spray environments requiring conformal coating
-
Marine: Fuel isolation valves, ballast valve controls
-
Chemical Processing: Corrosive environments benefiting from conformal coating
Comparison with Competing Products
| Feature | GE IS200VSVOH1BDC | Siemens 6ES7-322 | Rockwell 1794-OB16 |
|---|---|---|---|
| Output Channels | 16 | 16 | 16 |
| Continuous Current | 2.5 A | 0.5 A | 2 A |
| Inrush Current | 6 A (150 ms) | No inrush support | No inrush support |
| Current Monitoring | ±5% accuracy | No | No |
| Wire-Break Detection | Yes | No | No |
| Conformal Coating | Standard | Optional | Optional |
| Temp Range | –25 to +70 °C | 0 to +55 °C | 0 to +55 °C |
| Humidity | 5–100% condensing | 5–90% | 5–90% |
| Fault Logging | 1000 events + waveforms | No | No |
The GE IS200VSVOH1BDC offers superior current handling, diagnostics, and environmental protection compared to competitors—making it the ideal choice for demanding solenoid valve control in harsh environments.
Selection Guidelines
-
When to choose:
-
Critical solenoid/isolation valve control requiring high reliability
-
Harsh environments (coastal, offshore, chemical, high-humidity)
-
Solenoids with high inrush current (>5 A)
-
Applications requiring predictive maintenance (current trending)
-
Vibration-prone installations (captive washer terminals)
-
Wide temperature variation environments (–25 to +70 °C)
-
-
When to upgrade from H1A/H1B: Replace existing boards with GE IS200VSVOH1BDC when conformal coating, extended temperature range, or expanded fault logging is required.
-
Load Verification: Verify solenoid inrush ≤6 A, holding ≤2.5 A per channel. Total module current ≤16 A.
-
Field Power: Provide dedicated 24 VDC power supply with capacity for all solenoids simultaneously (16 A max).
-
Wiring: Use 16–18 AWG for 2.5 A loads; use shielded cables for long runs.
-
Coating Verification: Inspect under UV (365 nm) upon receipt—uniform fluorescence indicates proper coating application.
-
Compatibility: Fits all Mark VIe VME64x racks. Requires processor board (VPRO series) with I/O Net connectivity and ControlST v6.5 or higher for full features.
Operational Precautions
-
Wiring: Follow GE wiring diagrams (GEH-6816)—correct polarity for external field power. Use shielded cables; ground shield at terminal board only.
-
Field Power: Properly size and fuse external 24 VDC supply (20 A fast-acting fuse recommended). Do not power solenoids from backplane.
-
Load Monitoring: Use Toolbox ST to view per-channel current readings. Establish baseline—trend increasing current (10%+ over baseline) indicates solenoid wear.
-
Wire-Break Detection: Test by disconnecting a field wire to verify alarm generation.
-
Short-Circuit Test: Simulate short to verify auto-shutdown and auto-retry (3 attempts) functionality.
-
LED Diagnostics: Green = output on; Amber = output off with fault; Red = module fault. Refer to GEH-6816 for blink code table.
-
Fault Log: Access 1000-event log via Toolbox ST for post-event analysis.
-
Coating Care: Use GE-approved cleaner; avoid solvents that dissolve coating. Inspect annually under UV—rework voids with approved coating per GE FSB.
-
Hot-Swap: Remove/insert slowly under power—processor auto-recognizes new module.
-
Spare Stock: Maintain 1 spare per 3–4 racks; “BDC” backward-compatible with all VSVOH1 sockets.
-
Annual Verification: Cycle solenoids during outages; monitor current and response times. Compare to baseline.
-
Thermal Derating: Above 60 °C, reduce total output current to 12 A max.
-
ESD: Handle by edges only with grounded wrist strap—coating does not protect connectors.
-
Storage: Anti-static bag with desiccant at –40 to +85 °C; rotate every 3 years for coating inspection.

GE IC695CHS012
A-B 1746-NO4V
A-B 1746-NO4V