Description
Product Parameters
| Parameter | Specification |
|---|---|
| Brand / Series | GE Mark VIe Speedtronic |
| Model | IS200VCMIH2 |
| Redundant Analog Inputs | 16 redundant pairs (32 total analog inputs) — upgraded from 8 pairs |
| Input Types | 4–20 mA, 0–10 V, ±10 V (software-selectable per channel) |
| ADC Resolution | 16-bit SAR (10–500 SPS) |
| Accuracy | ±0.05% FS |
| Redundancy Logic | Automatic failover (hardware-based, < 10 ms) |
| Input Impedance | 250 Ω (current mode), > 1 MΩ (voltage mode) |
| Filtering | Programmable low-pass filter (1–50 Hz) |
| Loop Power | 24 VDC (externally supplied only) |
| Isolation | 2000 VAC (field-to-system) |
| CMRR | >110 dB @ 50/60 Hz |
| Diagnostics | Open-circuit detection, over/under-range detection, loop power fault monitoring, channel mismatch detection, primary/secondary status monitoring, reference validation |
| Status Indication | 16 green LEDs (primary active), 16 green LEDs (redundant active), 32 red LEDs (fault), 2 red summary fault LEDs, 1 yellow LED (reference/calibration status) |
| Operating Temperature | –40°C to +70°C |
| Storage Temperature | –55°C to +85°C |
| Mounting | VME rack-mount terminal board with front-panel I/O connectors |
| Backplane Interface | VME64x (A24/A32, D16/D32/D64) |
| EMC Compliance | IEC 61000-4 Level 4 |
Advantages & Key Features
-
Extended Redundant Capacity: IS200VCMIH2 provides 16 redundant analog input pairs with automatic failover (< 10 ms), ensuring uninterrupted critical signal monitoring—double the capacity of IS200VCMIH1B (8 pairs).
-
High Channel Density: 16 redundant pairs (32 total inputs) in a single VME slot.
-
Enhanced Accuracy: ±0.05% FS accuracy provides high measurement precision.
-
Extended Temperature Range: –40°C to +70°C operation makes IS200VCMIH2 suitable for extreme environments.
-
Enhanced Isolation: 2000 VAC isolation and >110 dB CMRR provide superior protection.
-
Flexible Input Configuration: Each channel supports 4–20 mA, 0–10 V, or ±10 V inputs via GE ToolboxST.
-
Comprehensive Diagnostics: Open-circuit, over/under-range, loop power fault, channel mismatch, primary/secondary status monitoring, and reference validation per channel.
-
High-Density Status Indication: 16 primary and 16 redundant status LEDs enable rapid on-site troubleshooting.
-
ToolboxST Integration: Full configuration, monitoring, and diagnostics via GE ToolboxST.
-
Drop-In Replacement: Direct replacement for IS200VCMIH1B, IS200VCMIH1BCB, and earlier redundant analog input terminal boards.
Application Fields
-
Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Redundant speed probes, critical pressure transmitters, critical temperature transmitters, vibration monitoring.
-
Combined Cycle Plants: Redundant HRSG pressure and temperature transmitters.
-
Compressor Stations: Redundant suction/discharge pressure transmitters.
-
Nuclear Power Plants: Critical analog monitoring where redundancy and high reliability are mandated.
-
Arctic & Desert Installations: Extreme-environment critical monitoring applications.
-
Safety-Critical Applications: Monitoring in safety instrumented systems (SIS).
Comparison with Competing Products
| Feature | GE IS200VCMIH2 | GE IS200VCMIH1B (8 pairs) | Competitor A (Redundant Analog) | Competitor B (Analog Input) |
|---|---|---|---|---|
| Redundant Pairs | 16 (32 inputs) | 8 (16 inputs) | 4 (8 inputs) | 0 |
| Accuracy | ±0.05% FS | ±0.05% FS | ±0.2% FS | ±0.15% FS |
| Failover Time | < 10 ms | < 10 ms | < 50 ms | N/A |
| Isolation | 2000 VAC | 2000 VAC | 1000 VAC | 500 VDC |
| Operating Temp | –40°C to +70°C | –40°C to +70°C | 0°C to 50°C | 0°C to 60°C |
| Reference Validation | Yes | Yes | No | No |
Key Advantage: IS200VCMIH2 provides 16 redundant analog input pairs—double the density of IS200VCMIH1B and four times that of competing modules—with ±0.05% FS accuracy, 2000 VAC isolation, extended –40°C to +70°C temperature range, and comprehensive diagnostics including reference validation, making it ideal for large turbine applications requiring high-density, high-reliability redundant analog monitoring in extreme environments.
Selection Guidelines & Recommendations
-
Redundancy Configuration: Determine critical analog signals requiring redundant monitoring—up to 16 redundant pairs per board.
-
Input Type: Configure 4–20 mA, 0–10 V, or ±10 V per channel in GE ToolboxST.
-
Loop Power: External 24 VDC supplies required—plan cabinet power distribution.
-
Diagnostic Configuration: Enable mismatch detection, status monitoring, and reference validation for critical circuits.
-
Controller Firmware: Requires Mark VIe processor firmware v9.0 or later.
-
Wiring Guidelines: Use shielded twisted-pair cables for analog signal wiring.
-
Spare Strategy: Keep one spare per turbine; lead times 8–14 weeks.
-
Retrofit: Direct replacement for IS200VCMIH1B—regenerate configuration in GE ToolboxST for 16-pair mapping.
Important Cautions
-
No Hot-Swap: De-energize rack before insertion/removal.
-
Input Polarity: Observe correct polarity for 4–20 mA loops and voltage inputs.
-
Loop Power: External 24 VDC required—ensure supplies are connected.
-
Grounding: Connect AGND to Mark VIe system ground at single star point.
-
Shield Termination: Ground signal cable shields only at cabinet end.
-
ESD Handling: Use grounded wrist straps; field repair not possible.
-
Temperature Rating: Verify cabinet ambient does not exceed +70°C or fall below –40°C.
-
Reference Validation: Yellow LED indicates reference drift—schedule factory recalibration if illuminated.
-
Redundancy Verification: Confirm both primary and secondary inputs are operational after installation.
-
Channel Mapping: With 16 redundant pairs (32 channels), verify field wiring maps to correct ToolboxST channel numbers.
-
Wiring Density: With 32 analog inputs, ensure adequate cabinet space and cable management.

A-B 22B-D010N104
ABB LC100S/SP7
A-B 1756-IT6I
SICK DFS60B-S4PK10000


Reviews