IS200VAICH1A GE

¥999.00

IS200VAICH1A is a Terminal Board within the GE Mark VIe Speedtronic control system, designed as a field termination and signal conditioning interface for analog input signals in turbine control applications. This board provides centralized termination for analog sensors such as pressure transmitters, temperature transmitters, flow meters, position transducers, and other 4–20 mA or voltage-output devices, connecting to the Mark VIe main VME-based controller processors via front-panel I/O cables. The IS200VAICH1A features integrated termination points with built-in signal conditioning including filtering, isolation, and diagnostics. It offers 16 isolated analog input channels with flexible input configuration and comprehensive diagnostics.

Category:

Description

Product Parameters

Parameter Specification
Brand / Series GE Mark VIe Speedtronic
Model IS200VAICH1A
Analog Inputs 16 isolated channels
Input Types 4–20 mA, 0–10 V, ±10 V (software-selectable per channel)
Input Range 0–20 mA, 4–20 mA, 0–5 V, 0–10 V, ±10 V
ADC Resolution 16-bit SAR with programmable sampling rate (10–500 SPS)
Accuracy ±0.1% FS (25°C), ±0.2% over full temperature range
Input Impedance 250 Ω (current mode), > 1 MΩ (voltage mode)
Filtering Programmable low-pass filter (1–50 Hz)
Loop Power 24 VDC (externally supplied only)
Isolation 1500 VAC (field-to-system)
CMRR >100 dB @ 50/60 Hz
Diagnostics Open-circuit detection, over/under-range detection, loop power fault monitoring
Status Indication 16 green LEDs (channel active), 2 red LEDs (diagnostic fault summary)
Operating Temperature –30°C to +65°C
Storage Temperature –55°C to +85°C
Mounting VME rack-mount terminal board with front-panel I/O connectors
Backplane Interface VME64x (A24/A32, D16/D32/D64)
EMC Compliance IEC 61000-4 Level 4

Advantages & Key Features

  • High Channel Density: 16 isolated analog inputs in a single VME slot—double the density of competing 8-channel modules.

  • Flexible Input Configuration: Each channel supports 4–20 mA, 0–10 V, or ±10 V inputs via GE ToolboxST.

  • Programmable Filtering: Onboard low-pass filter (1–50 Hz) optimizes noise rejection vs. response speed.

  • Comprehensive Diagnostics: Open-circuit, over/under-range, and loop power fault monitoring per channel.

  • Wide Input Compatibility: Accommodates both current and voltage sensors without external signal conditioners.

  • Opto-Isolation: 1500 VAC isolation protects the Mark VIe backplane from field wiring faults.

  • ToolboxST Integration: Full configuration, calibration, and diagnostics via GE ToolboxST.

  • Drop-In Replacement: Direct replacement for earlier GE analog input terminal boards.

Application Fields

  • Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Fuel gas pressure/flow, steam pressure/temperature, lube oil pressure/temperature, cooling water pressure, valve position feedback.

  • Combined Cycle Plants: HRSG feedwater flow, steam drum pressure, condensate flow.

  • Compressor Stations: Suction/discharge pressure, gas flow, vibration transducers.

  • Aeroderivative Turbines: Fuel flow, oil pressure, guide vane position.

Comparison with Competing Products

Feature GE IS200VAICH1A Competitor A (Analog Input Module) Competitor B (Analog Input Module)
Analog Inputs 16 isolated 8 isolated 8 isolated
Input Types 4–20 mA, 0–10 V, ±10 V 4–20 mA only 4–20 mA, 0–10 V
Accuracy ±0.1% FS ±0.2% FS ±0.15% FS
Isolation 1500 VAC 1000 VAC 500 VDC
Operating Temp –30°C to +65°C 0°C to 50°C 0°C to 60°C

Key AdvantageIS200VAICH1A provides 16 isolated analog inputs—double the density of competing modules—with flexible input configuration and comprehensive diagnostics, reducing rack space for turbine analog input applications.

Selection Guidelines & Recommendations

  • Input Type: Configure 4–20 mA, 0–10 V, or ±10 V per channel in GE ToolboxST.

  • Loop Power: External 24 VDC supplies required—plan cabinet power distribution accordingly.

  • Filtering: Use 1–10 Hz for temperature/pressure, 20–50 Hz for dynamic signals.

  • Controller Firmware: Requires Mark VIe processor firmware v7.0 or later.

  • Spare Strategy: Keep one spare per turbine; lead times 6–8 weeks.

  • Retrofit: Direct replacement—regenerate configuration in GE ToolboxST.

Important Cautions

  1. No Hot-Swap: De-energize rack before insertion/removal.

  2. External Loop Power Required: No internal loop power—ensure 24 VDC supplies are connected.

  3. Input Overload: Sustained input >30 V or >50 mA may damage input circuitry.

  4. Grounding: Connect AGND to Mark VIe system ground at single star point.

  5. Shield Termination: Ground shields only at cabinet end.

  6. ESD Handling: Use grounded wrist straps; field repair not possible.

  7. Filtering Trade-Off: Lower cutoff = better noise rejection but more signal delay.

  8. Channel Mapping: With 16 channels, verify field wiring maps to correct ToolboxST channel assignments.

A-B 1746-A13
HONEYWELL FC-DCOM-232/485
ASCO VCEVCM8551G321*24VDC
NI PXI-6052E