Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200SCTLG1A |
| Serial Interfaces | 2× configurable serial ports (RS-232 / RS-485) |
| Control Logic Functions | Logic processing, sequence control, logic coordination |
| Terminal Interface | Terminal management, operator interface, status display |
| Logic Gateway | Logic-based data routing, protocol conversion |
| Communication | Serial interfaces, highway integration |
| Supported Protocols | Modbus RTU, GE serial protocols |
| Functions | Logic processing, terminal interface, gateway communication |
| Power | +5V DC / 2.0A, ±15V DC / 0.4A |
| Temp Range | -30°C to +65°C |
| MTBF | > 108,000 hours |
| Revision Note | “A” suffix = specific hardware/firmware configuration |
Advantages and Key Features
Dedicated Serial, Control Logic, and Terminal Gateway: The IS200SCTLG1A provides specialized control logic processing, terminal interface management, and logic-based gateway communication.
Control Logic Processing: The IS200SCTLG1A handles logic coordination and sequence control.
Terminal Interface: Provides operator interface and status display.
Logic Gateway: Enables logic-based data routing and protocol conversion.
Application Fields and Case Studies
Used in control logic applications, terminal interface management, and logic-based gateway communication for integrated control systems. In a 600 MW plant, the IS200SCTLG1A provided reliable control logic and terminal interface management.
Comparison with Competing Products
| Dimension | IS200SCTLG1A | IS200SCNVG1ADC | IS200SAMBH1A |
|---|---|---|---|
| Primary Function | Control logic + terminal gateway | Signal conversion + voltage | Serial + analog + module |
| Logic Processing | Yes | No | No |
| Terminal Interface | Yes | No | No |
| VME Integration | Direct | Direct | Direct |
Selection Recommendations
Choose IS200SCTLG1A for control logic processing, terminal interface management, and logic-based gateway applications. Verify compatibility with your specific logic and terminal requirements. Deploy for integrated control systems.
Precautions and Important Notes
Use ESD-safe handling. Verify field wiring and serial connections. Confirm compatibility with your specific logic and terminal requirements. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix variants in redundant pairs. Allow 30 seconds boot time. Test all logic, terminal, and gateway functions during commissioning. The IS200SCTLG1A is critical for control logic and terminal management – ensure all settings are verified before placing in service. Ensure serial cabling does not exceed maximum recommended length. Regular verification of logic processing and terminal interface performance is recommended. Ensure communication cabling does not exceed maximum recommended length.

ABB 3BHL000511P0003 NTAC-02
IAI RCA-S-S5
ENTERASYS C2RPS-PSM
A-B 1756-PA75


Reviews
There are no reviews yet.