Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200IVSHG1A |
| Solenoid Outputs | 8–16 isolated solenoid control outputs |
| Digital Inputs | 8–16 status/feedback inputs |
| Gateway Functions | Solenoid control, valve coordination, gateway communication |
| Supported Devices | Solenoid valves, proportional valves, on/off valves |
| Communication | Highway integration (GE proprietary) |
| Power | +5V DC / 2.5A, ±15V DC / 0.5A |
| Temp Range | -30°C to +65°C |
| MTBF | > 105,000 hours |
| Revision Note | “A” suffix = specific hardware/firmware configuration |
Advantages and Key Features
Dedicated Valve Solenoid Highway Gateway: The IS200IVSHG1A provides specialized solenoid valve control and gateway communication.
Multiple Solenoid Outputs: Handles 8–16 solenoid control outputs.
Status/Feedback Inputs: The IS200IVSHG1A monitors valve status and feedback signals.
Gateway Communication: Integrates solenoid valve control with control networks.
Application Fields and Case Studies
Used in solenoid valve control applications, valve coordination systems, and highway-integrated valve control. In a 600 MW plant, the IS200IVSHG1A provided reliable solenoid valve control and gateway communication.
Comparison with Competing Products
| Dimension | IS200IVSHG1A | IS200IVFBG1AAA | IS200FHVBG1ABA |
|---|---|---|---|
| Primary Function | Solenoid control + gateway | Valve feedback gateway | Valve bridge |
| Solenoid Outputs | Yes | No | No |
| Gateway Function | Yes | Yes | No |
| VME Integration | Direct | Direct | Direct |
Selection Recommendations
Choose IS200IVSHG1A for solenoid valve control and gateway applications. Verify compatibility with your specific solenoid valves and control requirements. Deploy for valve control and monitoring applications. Confirm rack power supply capacity.
Precautions and Important Notes
Use ESD-safe handling. Verify field wiring and solenoid connections. Confirm compatibility with your specific solenoid valves. Never interrupt firmware updates. Board draws 2.5A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix variants in redundant pairs. Allow 30 seconds boot time. Test all solenoid control and gateway functions during commissioning. The IS200IVSHG1A is critical for solenoid valve control – ensure all settings are verified before placing in service. Ensure solenoid cabling is properly sized for current requirements. Regular verification of valve operation is recommended. Ensure highway cabling does not exceed maximum recommended length.