HONEYWELL 51402455-100 MP-DNCF02-200

¥999.00

The HONEYWELL 51402455-100 MP-DNCF02-200 is a high-performance DeviceNet communication control module engineered for Honeywell’s Experion PKS and C300 distributed control systems. This interface unit provides seamless connectivity between Honeywell controllers and DeviceNet field device networks, enabling integration of smart actuators, sensors, and motor starters into the plant-wide automation architecture. The HONEYWELL 51402455-100 MP-DNCF02-200 serves as both master scanner and protocol converter, eliminating the need for standalone gateway devices in DeviceNet-enabled process applications.

Category:

Description

Product Overview
The HONEYWELL 51402455-100 MP-DNCF02-200 is a high-performance DeviceNet communication control module engineered for Honeywell’s Experion PKS and C300 distributed control systems. This interface unit provides seamless connectivity between Honeywell controllers and DeviceNet field device networks, enabling integration of smart actuators, sensors, and motor starters into the plant-wide automation architecture. The HONEYWELL 51402455-100 MP-DNCF02-200 serves as both master scanner and protocol converter, eliminating the need for standalone gateway devices in DeviceNet-enabled process applications.

Technical Specifications
The HONEYWELL 51402455-100 MP-DNCF02-200 operates on 24 VDC power with 6 W typical consumption and features a dedicated DeviceNet communication port compliant with ODVA specifications. The module supports baud rates of 125 kbps, 250 kbps, and 500 kbps with automatic configuration detection. It provides galvanic isolation of 500 VDC between DeviceNet and controller interfaces. The HONEYWELL 51402455-100 MP-DNCF02-200 incorporates 8 MB of non-volatile memory for device profile storage and supports up to 63 DeviceNet slave devices per network segment. Housed in a compact metal enclosure measuring 120 mm x 100 mm x 50 mm, the unit mounts on standard 35 mm DIN rail and features removable Phoenix Contact style terminal blocks. Operating temperature range is -20°C to +60°C with 5% to 95% non-condensing humidity tolerance.

Key Features and Advantages

  • Explicit Messaging: The HONEYWELL 51402455-100 MP-DNCF02-200 supports both polled and change-of-state I/O messaging with configurable packet rates up to 10 ms.

  • Integrated Webserver: Built-in diagnostics interface accessible via standard web browser for real-time DeviceNet traffic monitoring and fault logging.

  • Automatic Device Detection: Scans the DeviceNet network upon startup and automatically builds the I/O mapping table, significantly reducing commissioning time.

  • Electronic Data Sheet Library: Preloaded EDS files for over 200 common DeviceNet devices including Rockwell PowerFlex drives and Honeywell SmartLine transmitters.

  • Redundant Media Support: Compatible with DeviceNet trunk and drop topologies with integral network termination detection.

Application Areas
The HONEYWELL 51402455-100 MP-DNCF02-200 is extensively deployed in automotive assembly plant paint finishing lines, where hundreds of DeviceNet-enabled spray robots and conveyor drives are integrated with Experion PKS batch management systems. A recent food and beverage facility in the Midwest utilized 12 HONEYWELL 51402455-100 MP-DNCF02-200 modules to modernize their aseptic filling lines, replacing obsolete Allen-Bradley scanners while preserving existing DeviceNet field wiring and devices. The module is also widely specified in water treatment chemical feed systems requiring precise coordination between Honeywell controllers and multiple variable frequency drives.

Competitive Comparison
Versus the Siemens SIMATIC ET 200pro DeviceNet master and Rockwell 1756-DNB, the HONEYWELL 51402455-100 MP-DNCF02-200 offers native integration with Honeywell’s CEE (Control Execution Environment) without requiring function block custom programming. While competitive scanners present DeviceNet data as simple arrays requiring extensive PLC logic for interpretation, the HONEYWELL 51402455-100 MP-DNCF02-200 maps device parameters directly to named process variables within the Experion engineering environment. Its embedded EDS library also eliminates the tedious manual EDS file installation required by generic DeviceNet masters.

Selection Guidelines and Precautions

  • Verify that your Experion PKS version is compatible with the HONEYWELL 51402455-100 MP-DNCF02-200; systems prior to R400 require a Control Builder update.

  • Confirm that total DeviceNet cable length does not exceed ODVA specifications for the selected baud rate; 500 kbps supports maximum 100 m trunk length.

  • The HONEYWELL 51402455-100 MP-DNCF02-200 requires 24 VDC power from a Class 2 SELV source; do not share power supplies with motors or solenoids.

  • Order the HONEYWELL 51402455-100 MP-DNCF02-200 with the companion 51402455-200 termination accessory for proper network biasing when installed at end of trunk.

  • Ensure all DeviceNet devices on the network have unique MAC IDs before connecting to the HONEYWELL 51402455-100 MP-DNCF02-200; duplicate addresses will prevent network startup.

  • Perform DeviceNet physical layer verification using a handheld network monitor prior to commissioning to identify unterminated stubs or incorrect grounding.