TRICONEX 1600071-001

¥2,299.00

The TRICONEX 1600071-001 is a specialized digital output module from the Triconex (a Schneider Electric brand) range of safety instrumented systems, specifically designed for their TMR (Triple Modular Redundant) Tricon or Trident controller platforms. This module serves as a critical safety-rated interface between the fault-tolerant logic solver and field actuation devices such as solenoid valves, motor starters, and alarm annunciators in safety shutdown systems. The primary function of the TRICONEX 1600071-001 is to receive processed, voted commands from the triple-redundant main processors and convert them into robust, isolated, and high-integrity output signals to drive final elements. Its design embodies the TMR principle, where three independent output channels are used to control a single field device, and a 2-out-of-3 voting logic is performed either internally or externally to ensure a single point of failure does not prevent a safe shutdown. The integration of this module into a safety loop is governed by rigorous safety lifecycle standards to ensure it meets the required Safety Integrity Level (SIL).

Category:

Description

Product Overview and Description

The TRICONEX 1600071-001 is a specialized digital output module from the Triconex (a Schneider Electric brand) range of safety instrumented systems, specifically designed for their TMR (Triple Modular Redundant) Tricon or Trident controller platforms. This module serves as a critical safety-rated interface between the fault-tolerant logic solver and field actuation devices such as solenoid valves, motor starters, and alarm annunciators in safety shutdown systems. The primary function of the TRICONEX 1600071-001 is to receive processed, voted commands from the triple-redundant main processors and convert them into robust, isolated, and high-integrity output signals to drive final elements. Its design embodies the TMR principle, where three independent output channels are used to control a single field device, and a 2-out-of-3 voting logic is performed either internally or externally to ensure a single point of failure does not prevent a safe shutdown. The integration of this module into a safety loop is governed by rigorous safety lifecycle standards to ensure it meets the required Safety Integrity Level (SIL).

Product Parameters and Specifications

  • Product Type: Triple Modular Redundant (TMR) Digital Output Module

  • Manufacturer Part Number (MPN): 1600071-001

  • Brand: Triconex (Schneider Electric)

  • System Compatibility: Tricon or Trident Safety Controllers (specific chassis and firmware compatibility must be verified).

  • Architecture: TMR design with three isolated output channels per point, each driven by a separate main processor.

  • Number of Points: Typically 8 or 16 points per module (specific to this part number).

  • Output Type: Likely a high-side switch (solid-state) or relay contact output rated for a specific voltage and current (e.g., 24V DC, 2A per channel).

  • Voting: The module may perform internal hardware voting on the three signals, or the voting may be accomplished via external relay logic (e.g., using a De-energize-to-Trip configuration).

  • Diagnostics: Extensive onboard diagnostics continuously monitor for field-side faults (short circuit, open circuit) and internal module health.

  • Isolation: High-grade isolation between each channel, between channels and the logic side, and between the module and the backplane.

  • Response Time: Very fast and deterministic, suitable for critical safety shutdowns.

  • Safety Certification: Certified for use in SIL 3 applications according to IEC 61508/61511 standards.

  • Status Indicators: Per-point LEDs and module health LEDs for power, communication, and fault status.

  • Connectors: Uses removable terminal blocks or connectors for field wiring.

Key Advantages and Features

The paramount advantage of the TRICONEX 1600071-001 is its inherent high safety availability and fault tolerance due to its TMR architecture. It provides a very high diagnostic coverage, detecting dangerous failures and allowing them to be announced before they compromise the safety function. The module is designed for hot-replaceability, allowing it to be swapped out without taking the safety system offline, which is crucial for maintaining process availability. Its robust output drivers are designed to handle inductive loads typical in industrial environments. The module’s behavior is fully deterministic and certified, providing assurance that it will perform its safety function reliably when demanded. Integration with the Triconex engineering environment (Tristation 1131) allows for seamless configuration, testing, and validation of the entire safety loop, including this output module.

Application Scenarios and Use Cases

This module is deployed in the highest-hazard process industries for Emergency Shutdown (ESD) and Fire & Gas (F&G) systems. In oil & gas, it is used to command shutdown valves (SDVs) on wellheads, pipelines, or process units. In petrochemical plants, it controls vent or dump valves on reactors and storage tanks. For power generation (especially gas turbines), it might drive actuators for fuel shut-off valves. In offshore platforms, it is integral to complex fire and gas suppression system actuation. Each output point of the TRICONEX 1600071-001 is typically responsible for a single, critical final element that must move to a safe state (de-energized or energized) upon a trip command from the safety logic solver.

Comparison with Competing Products

The TRICONEX 1600071-001 competes with other high-integrity safety output modules from manufacturers like HIMA (F7xxx series)Rockwell Automation (GuardLogix with safety output cards)Siemens (S7-400F/ET200SP F modules), and ABB (Symphony Plus S+). Compared to standard digital output modules or even 1oo1D (single channel with diagnostics) safety modules, the TMR design of the 1600071-001 offers a fundamentally higher level of fault tolerance and availability. Versus other TMR systems, Triconex is often noted for its mature, field-proven technology and its focus on the process industries. The choice between it and a competing system often depends on corporate standards, existing plant footprint, and specific application requirements for diagnostics and voting philosophy.

Selection Guidelines and Important Notes

Selection Advice:

  1. Safety Requirement Specification (SRS): The use of a TRICONEX 1600071-001 must be justified by a safety lifecycle analysis defining the required SIL and the voting architecture (e.g., 2oo3).

  2. System Compatibility: Verify the module is compatible with the specific Tricon/Trident chassis model, backplane, and controller firmware version.

  3. Load Analysis: Carefully match the output specifications (voltage, current, inrush capability) to the connected field device (solenoid, relay coil). Use external relays for high-power loads.

  4. Wiring Philosophy: Understand the safety system’s wiring philosophy (De-energize-to-Trip vs. Energize-to-Trip) and wire the field device and its power supply accordingly.

  5. External Voting: If the module does not perform internal voting, design and implement the external 2oo3 voting relay logic correctly, as this is part of the certified safety function.

Important Precautions:

  • Safety System Procedures: Installation, testing, and modification must be performed by qualified safety system engineers following a formal Management of Change (MOC) process.

  • Proof Testing: The entire safety loop, including the output function of the TRICONEX 1600071-001, must undergo regular proof testing as defined in the SRS to reveal latent failures.

  • Do Not Bypass Diagnostics: Never disable or ignore diagnostic alarms. They are essential for maintaining the module’s Safe Failure Fraction (SFF) and the system’s SIL rating.

  • Use Certified Components: For external voting relays or barriers, use components that are compatible and, if required, certified for the safety loop.

  • Documentation: The Triconex Hardware Manual and the specific Safety Manual for the 1600071-001 are governing documents. Adhere strictly to their requirements for installation, operation, and maintenance.

  • Hot-Swap Procedure: If performing a hot-swap, follow the documented procedure exactly to avoid disturbing the control network or causing a nuisance trip.

1C31179G01 PLC
IC693PBM200-DE PLC
TRICONEX-3805E
1398-DDM-075
1FK7063-2AF71-1RH0
4PP250.0571-K01
E93DA11314B531KSD1-32 PLC
1756-RIO PLC
PFEA111-20 CPU
KMRSAN12STATICMIXER PLC

Reviews

There are no reviews yet.

Be the first to review “TRICONEX 1600071-001”

Your email address will not be published. Required fields are marked *

Post comment