HIMA X-COM01

¥999.00

HIMA X-COM01 is a compact, high-reliability communication interface module designed for HIMA HIMatrix safety instrumented systems (SIS), specializing in secure data exchange between SIS controllers and external devices/networks. As a cost-effective connectivity solution in HIMA’s portfolio, HIMA X-COM01 supports core industrial protocols (Modbus RTU/TCP, HIMA SafetyBUS p) and is optimized for small-to-medium scale safety systems in oil & gas, petrochemical, and manufacturing industries. In a small refinery’s burner management system, HIMA X-COM01 transmits flame detection status to the central DCS; in a chemical packaging plant, HIMA X-COM01 syncs safety interlock data with a local PLC; in a water treatment facility, HIMA X-COM01 enables remote monitoring of SIS alarms via Modbus TCP. Additionally, HIMA X-COM01 features plug-and-play configuration and rugged design, making it ideal for decentralized safety applications with limited rack space.

Category:

Description

1. Product Overview

HIMA X-COM01 is a compact, high-reliability communication interface module designed for HIMA HIMatrix safety instrumented systems (SIS), specializing in secure data exchange between SIS controllers and external devices/networks. As a cost-effective connectivity solution in HIMA’s portfolio, HIMA X-COM01 supports core industrial protocols (Modbus RTU/TCP, HIMA SafetyBUS p) and is optimized for small-to-medium scale safety systems in oil & gas, petrochemical, and manufacturing industries. In a small refinery’s burner management system, HIMA X-COM01 transmits flame detection status to the central DCS; in a chemical packaging plant, HIMA X-COM01 syncs safety interlock data with a local PLC; in a water treatment facility, HIMA X-COM01 enables remote monitoring of SIS alarms via Modbus TCP. Additionally, HIMA X-COM01 features plug-and-play configuration and rugged design, making it ideal for decentralized safety applications with limited rack space.

2. Product Parameters

2.1 Core Communication Specifications

  • Supported Protocols: Modbus RTU (RS-485), Modbus TCP (Ethernet), HIMA SafetyBUS p
  • Network Interface: 1× Gigabit Ethernet port (RJ45), 1× RS-485 port (terminal block)
  • Data Transfer Rate: 1 Gbps (Ethernet), 115.2 kbps (RS-485)
  • Latency: ≤5ms (Modbus TCP), ≤10ms (Modbus RTU)
  • Addressing: Static IP/DHCP (Ethernet), Modbus slave ID configurable (1-247)

2.2 Electrical & System Parameters

  • Power Supply: 24V DC (single input), power consumption ≤8W
  • Compatibility: HIMA HIMatrix F65/F75 controllers, third-party Modbus-compatible DCS/PLC/HMI (Siemens, Allen-Bradley, Schneider)
  • Diagnostic Features: Link status monitoring, protocol error detection, power fault alerts, LED indicators (power, Ethernet, RS-485, fault)
  • Cybersecurity: Basic IP filtering, Modbus access control lists (ACL)
  • Redundancy: Optional Ethernet redundancy (via external switch), no native module redundancy

2.3 Environmental & Mechanical Parameters

  • Operating Temperature: -20°C to +60°C (industrial-grade range)
  • Storage Temperature: -40°C to +85°C
  • Relative Humidity: 5% to 95% (non-condensing), IP20 protection
  • Vibration Resistance: 5-2000Hz, 2g (IEC 60068-2-6, X/Y/Z axes)
  • Shock Resistance: 15g (11ms half-sine wave, IEC 60068-2-27)
  • Mounting: Hima HIMatrix rack-mounted, compact form factor (half-width module)
  • Dimensions: 24mm (W) × 220mm (H) × 180mm (D), space-saving design

2.4 Certifications & Compliance

  • Safety Certifications: SIL 2 (IEC 61508/61511), TÜV Rheinland
  • Industry Certifications: CE, UL/cUL Class 1 Div 2, FCC Class A, RoHS
  • MTBF: ≥600,000 hours (per Telcordia SR-332 standards)

3. Advantages & Features

  1. Dual Protocol Support (Wired)HIMA X-COM01 combines Modbus RTU (RS-485) and Modbus TCP (Ethernet) in a single compact module, enabling connectivity to both legacy serial devices and modern Ethernet-based systems without additional hardware.
  2. Space-Saving Design: As a half-width module, HIMA X-COM01 maximizes rack space utilization—critical for decentralized safety systems or small control cabinets with limited room for expansion.
  3. Plug-and-Play Configuration: Intuitive setup via Hima Safety Workbench software (Modbus mapping, IP configuration) reduces commissioning time, while pre-defined templates for common third-party systems simplify integration.
  4. Rugged Industrial Performance: The -20°C to +60°C operating range and robust vibration/shock resistance ensure reliable operation in harsh environments, from outdoor pump stations to indoor manufacturing floors.
  5. Cost-Effective ConnectivityHIMA X-COM01 delivers core communication functionality at a lower price point than multi-protocol redundant modules, making it ideal for small-scale SIS applications with basic connectivity needs.

4. Application Fields & Cases

4.1 Application Fields

  • Oil & Gas: Small refinery burner management system (BMS) communication, pipeline valve SIS remote monitoring, offshore platform skid-mounted SIS data transmission
  • Petrochemical: Chemical packaging plant safety interlock-PLC integration, storage tank level SIS-HMI communication
  • Water/Wastewater: Treatment plant pump SIS-DCS connectivity, reservoir safety alarm remote reporting
  • Manufacturing: Food processing line safety interlock-HMI monitoring, automotive assembly line SIS-PLC data exchange

4.2 Typical Cases

  1. Small Refinery BMS-DCS Integration: A U.S. regional refinery deployed HIMA X-COM01 modules to connect 2 Hima HIMatrix BMS controllers with a Modbus TCP-based DCS. The module’s compact design fit into limited rack space, while Modbus TCP support enabled real-time transmission of flame detector and fuel valve status to the DCS, improving operator visibility and reducing false alarm response time by 25%.
  2. Water Treatment Plant SIS Remote Monitoring: A European water treatment facility used HIMA X-COM01 to link pump safety interlocks (overload, low pressure) to a central Modbus RTU HMI. The RS-485 port provided reliable long-distance communication (up to 1.2km) between the remote pump station and control room, while diagnostic features alerted maintenance teams to a faulty sensor before it caused a pump shutdown.
  3. Chemical Packaging Plant Safety-PLC Sync: A German chemical packaging plant integrated HIMA X-COM01 into its HIMatrix SIS to sync safety interlock data (door switches, emergency stops) with a Siemens S7 PLC. The module’s plug-and-play configuration reduced commissioning time by 40%, and IP filtering prevented unauthorized access to safety data from the plant’s general network.

5. Competitive Comparison

Parameter HIMA X-COM01 Competitor A (Full-Width Modbus Interface) Competitor B (Serial-Only Interface)
Form Factor Half-width Full-width Half-width
Supported Protocols Modbus RTU/TCP Modbus TCP only Modbus RTU only
Safety Certification SIL 2 SIL 2 No SIL Certification
Power Consumption ≤8W ≤12W ≤6W
Ethernet Port 1× Gigabit 1× Fast Ethernet (100Mbps) None
MTBF ≥600,000 hours ≥500,000 hours ≥400,000 hours

6. Selection Suggestions & Precautions

6.1 Selection Suggestions

  1. Application Scale & Space Needs: Choose HIMA X-COM01 for small-to-medium SIS applications with limited rack space (e.g., skid-mounted systems, decentralized safety nodes); full-width redundant modules are better for large-scale, mission-critical systems.
  2. Protocol Requirements: Opt for HIMA X-COM01 if both Modbus RTU (legacy devices) and Modbus TCP (modern systems) connectivity is needed; single-protocol modules suffice for dedicated serial/Ethernet environments.
  3. Safety Level: Select HIMA X-COM01 for SIL 2 applications (e.g., packaging plants, water treatment); upgrade to HIMA X-A13201 for SIL 3 requirements (e.g., refineries, power plants).

6.2 Precautions

  1. Installation Guidelines:
    • Install HIMA X-COM01 in Hima-certified HIMatrix racks only; ensure proper grounding (≤4Ω) for the RS-485 port to minimize signal interference in industrial environments.
    • Use shielded twisted-pair cable for RS-485 connections (maximum distance 1.2km) and Cat 5e/Cat 6 cable for Ethernet to maintain Gigabit speeds.
  2. Configuration Notes:
    • Set up Modbus ACLs and IP filtering via Safety Workbench to restrict access to safety data—avoid exposing the module directly to untrusted networks.
    • Test Ethernet redundancy (if used with an external switch) before system commissioning to ensure failover works as expected for critical data paths.
  3. Troubleshooting:
    • For Modbus communication faults: Check slave ID/IP configuration, verify cable connections, and use the module’s LED indicators to identify link/power issues.
    • For RS-485 signal degradation: Ensure proper termination (120Ω resistor) at the end of the bus and avoid running RS-485 cables parallel to high-voltage power lines.
  4. Maintenance:
    • Update module firmware annually (via Safety Workbench) to address security vulnerabilities and improve protocol compatibility.
    • Inspect Ethernet/RS-485 connectors every 12 months for corrosion or loose pins—clean with compressed air to prevent connection failures.
    • Stock spare HIMA X-COM01 modules for critical decentralized applications, as replacement lead times may be 2-4 weeks for specialized interface components.

SIEMENS6GK1105-2AA10
SIEMENSFD63T150 PLC
SIEMENS16413-15 PLC
SIEMENS6ES5944-7UB21 PLC DCS
SIEMENS6ES7952-0KH00-0AA0 PLC
SIEMENS6ES5376-0AA21 PLC
SIEMENS6ES5760-0AB11 PLC
SIEMENS6ES5377-0AB41 PLC
SIEMENS6ES5375-1LR41 PLC
SIEMENSNKDG/A PLC

Reviews

There are no reviews yet.

Be the first to review “HIMA X-COM01”

Your email address will not be published. Required fields are marked *

Post comment