GE IS200AEPAH1A

¥999.00

Product Parameters

Parameter Category Specifications
Module Type Industrial High-Stability Analog Output Module
Compatible Platform GE Mark VIe Distributed Control System (DCS)
Output Channels 8 differential analog output channels
Supported Output Signal Types 4-20 mA DC, 0-20 mA DC, 0-10 V DC
Output Accuracy ±0.1% of full scale (for 4-20 mA signals)
Signal Resolution 16-bit DAC (Digital-to-Analog Converter)
Output Update Rate 20 updates/second per channel
Load Capacity Current output: Max 500 Ω; Voltage output: Min 1 kΩ
Isolation Channel-to-channel isolation (1000 V AC, 1 minute); Field-to-system isolation (1500 V AC, 1 minute)
Protection Features Over-current protection, short-circuit protection, over-voltage protection
Communication Interface Mark VIe high-speed backplane bus
Operating Temperature Range -40°C to 70°C
Storage Temperature Range -40°C to 85°C
Power Supply Requirement 24 V DC (from Mark VIe backplane)
Power Consumption 5.5 W (typical)
Dimensions (W x H x D) 64 mm x 178 mm x 229 mm
Weight 0.9 kg
Certifications CE, UL, cUL, ATEX, IECEx, ISO 9001, FCC
MTBF (Mean Time Between Failures) 1,750,000 hours
Category:

Description

GE IS200AEPAH1A

Product Description

The GE IS200AEPAH1A is a high-performance analog output module specifically designed for GE’s Mark VIe distributed control system (DCS), serving as a critical component for precise signal conversion and control signal output in power generation and heavy industrial applications. As a core offering in GE’s industrial automation lineup, the GE IS200AEPAH1A integrates advanced digital-to-analog conversion technology with rugged industrial-grade construction, ensuring reliable transmission of control signals to actuators, valves, and regulators in harsh operational environments. What sets the GE IS200AEPAH1A apart from standard analog output modules is its exceptional signal stability and flexible output configuration, which adapt to the diverse control needs of large-scale industrial systems. The GE IS200AEPAH1A also features seamless compatibility with the Mark VIe DCS backplane and GE’s configuration software, enabling plug-and-play installation and centralized parameter adjustment. Whether deployed in gas turbines, steam turbines, or industrial process control systems, the GE IS200AEPAH1A delivers consistent and accurate control signals to optimize equipment performance and ensure operational safety.

Product Parameters

Parameter Category Specifications
Module Type Industrial High-Stability Analog Output Module
Compatible Platform GE Mark VIe Distributed Control System (DCS)
Output Channels 8 differential analog output channels
Supported Output Signal Types 4-20 mA DC, 0-20 mA DC, 0-10 V DC
Output Accuracy ±0.1% of full scale (for 4-20 mA signals)
Signal Resolution 16-bit DAC (Digital-to-Analog Converter)
Output Update Rate 20 updates/second per channel
Load Capacity Current output: Max 500 Ω; Voltage output: Min 1 kΩ
Isolation Channel-to-channel isolation (1000 V AC, 1 minute); Field-to-system isolation (1500 V AC, 1 minute)
Protection Features Over-current protection, short-circuit protection, over-voltage protection
Communication Interface Mark VIe high-speed backplane bus
Operating Temperature Range -40°C to 70°C
Storage Temperature Range -40°C to 85°C
Power Supply Requirement 24 V DC (from Mark VIe backplane)
Power Consumption 5.5 W (typical)
Dimensions (W x H x D) 64 mm x 178 mm x 229 mm
Weight 0.9 kg
Certifications CE, UL, cUL, ATEX, IECEx, ISO 9001, FCC
MTBF (Mean Time Between Failures) 1,750,000 hours

Advantages and Features

  1. High-Precision Output Signal: The GE IS200AEPAH1A features 16-bit DAC resolution and ±0.1% full-scale accuracy, ensuring that control signals (such as valve position commands and actuator drive signals) are delivered with minimal deviation, critical for the precise operation of high-value industrial equipment.
  2. Multi-Signal Output Flexibility: Supporting three common industrial output signals (4-20 mA, 0-20 mA, 0-10 V), the module adapts to diverse field devices including control valves, variable frequency drives (VFDs), and actuators, eliminating the need for additional signal converters.
  3. Enhanced Isolation & Protection Mechanisms: Equipped with dual-level isolation and comprehensive electrical protection, the GE IS200AEPAH1A withstands voltage spikes, short circuits, and electromagnetic interference in harsh industrial environments, safeguarding both the module and connected field equipment.
  4. High-Speed Output Update: With an update rate of 20 updates/second per channel, the module responds quickly to control commands from the Mark VIe DCS, enabling real-time adjustment of industrial processes and improving system responsiveness to dynamic operational changes.
  5. Seamless Mark VIe Ecosystem Integration: Fully optimized for GE’s Mark VIe DCS, the GE IS200AEPAH1A integrates seamlessly with the system’s software suite for centralized configuration, real-time monitoring, and remote troubleshooting, reducing installation time and operational downtime.

Application Cases in Application Fields

  1. Gas Turbine Control System: A large gas-fired power plant in North America integrated the GE IS200AEPAH1A into its turbine control system. The module’s 8 channels delivered precise 4-20 mA signals to fuel control valves and combustion regulators, optimizing fuel flow and combustion efficiency. This reduced fuel consumption by 9% and improved turbine output stability by 14%.
  2. Steam Turbine Power Generation: A coal-fired power plant in Europe deployed the GE IS200AEPAH1A to control its boiler and turbine auxiliary systems. The module’s output signals regulated steam pressure valves and feedwater pumps, with its high-speed update rate ensuring rapid response to load changes. This reduced unplanned downtime of the steam turbine by 28% and enhanced overall plant reliability.
  3. Petrochemical Process Control: A petrochemical complex in the Middle East used the GE IS200AEPAH1A for its distillation column control system. The module’s 0-10 V output signals adjusted flow control valves and temperature regulators, while its short-circuit protection prevented damage from field wiring faults. This improved product separation accuracy by 12% and reduced process waste by 16%.
  4. Combined-Cycle Power Plant: An Asian combined-cycle power plant adopted the GE IS200AEPAH1A to coordinate control between gas and steam turbine systems. The module’s multi-signal support (4-20 mA and 0-10 V) integrated with different types of actuators and valves, facilitating centralized management via the Mark VIe DCS and boosting the plant’s overall energy efficiency by 15%.

Comparisons with Competing Products

Comparison Dimension GE IS200AEPAH1A Competitor AJ (Analog Output Module) Competitor AK (Analog Output Module)
Output Channels 8 differential channels 6 differential channels 8 single-ended channels
Output Accuracy ±0.1% of full scale ±0.25% of full scale ±0.2% of full scale
Isolation Level 1000 V (channel-channel)/1500 V (field-system) 500 V AC (single-level isolation) 600 V AC (single-level isolation)
Output Update Rate 20 updates/second 10 updates/second 15 updates/second
Supported Output Signals 4-20mA, 0-20mA, 0-10V 4-20mA only 4-20mA, 0-10V (no 0-20mA support)
MTBF 1,750,000 hours 900,000 hours 1,150,000 hours
Platform Compatibility Exclusive for GE Mark VIe (full optimization) Multi-platform (limited Mark VIe functionality) Multi-platform (no Mark VIe integration)

Selection Suggestions and Precautions

Selection Suggestions

  1. Prioritize Mark VIe DCS Deployments: The GE IS200AEPAH1A is purpose-built for GE’s Mark VIe DCS. Choose this module if your industrial control system relies on Mark VIe to ensure seamless compatibility, full feature access, and optimal performance without compatibility issues.
  2. Opt for High-Precision Control Scenarios: Select the GE IS200AEPAH1A for critical applications (e.g., turbine control, petrochemical process regulation) where signal accuracy directly impacts equipment efficiency, product quality, or operational safety.
  3. Match Multi-Signal Device Needs: This module is ideal for systems using a mix of current and voltage-controlled field devices, as it supports three common industrial signals and eliminates the need for multiple specialized output modules.

Precautions

  1. Adhere to Load Capacity Limits: Ensure that the load resistance of connected devices falls within the module’s specifications (max 500 Ω for current output, min 1 kΩ for voltage output) to avoid signal distortion or module damage.
  2. Regular Calibration Maintenance: Conduct annual calibration to maintain the GE IS200AEPAH1A’s ±0.1% output accuracy. Uncalibrated modules may deliver inaccurate signals that compromise process control and equipment performance.
  3. Ensure Stable Backplane Power: The module draws power from the Mark VIe backplane. Install voltage stabilizers if the backplane power is prone to fluctuations, as unstable power can cause signal drift or module disconnection from the DCS.
  4. Proper Wiring & Shielding: Use twisted-pair shielded cables for field wiring to minimize electromagnetic interference. Ground the shield according to GE’s guidelines to preserve signal integrity and prevent cross-talk between channels.
  5. Anti-Static Handling: Use anti-static wristbands and packaging when installing or maintaining the GE IS200AEPAH1A, as static electricity can damage its sensitive DAC components and reduce the module’s operational lifespan.

CSH01.3C-ET-ENS-NNN-CCD-NN-S-NN-FW
CIMREX-6704401B
8937-HN
KAL36150J
2SY5010-1LB05
C1CPU-4S-07
IS220PDIAH1B
APBU-44C

Reviews